An Experimental Comparison of Horizontal Resistance of Single Suction Pile and Group Suction Piles

Juhyung Lee, Hakman Kim, Jinwoo Cho
{"title":"An Experimental Comparison of Horizontal Resistance of Single Suction Pile and Group Suction Piles","authors":"Juhyung Lee, Hakman Kim, Jinwoo Cho","doi":"10.1115/OMAE2018-77192","DOIUrl":null,"url":null,"abstract":"In this study, a new type of suction pile foundation for floating structures, namely group suction piles, was proposed to improve the shortcomings of conventional single suction piles. Small-scale model tests were performed to estimate the horizontal behavior of single suction piles and group suction piles with different pile spacing (2, 3 and 4 times the pile diameter). The horizontal behavior of group suction piles with different pile spacing was analyzed for various loading locations based on the model tests. For the given group pile configurations (a group pile having 9 component piles with a pile formation of 3 × 3), the horizontal resistance increased with increasing pile spacing. The maximum ultimate horizontal resistances were found at the loading locations of 50% of the embedded depth. Unlikely in the single suction pile case, the significantly maintained residual resistances were found for group suction piles. The residual resistances of group suction piles were at least higher than 40% of the corresponding ultimate horizontal resistances.","PeriodicalId":106551,"journal":{"name":"Volume 9: Offshore Geotechnics; Honoring Symposium for Professor Bernard Molin on Marine and Offshore Hydrodynamics","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 9: Offshore Geotechnics; Honoring Symposium for Professor Bernard Molin on Marine and Offshore Hydrodynamics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/OMAE2018-77192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a new type of suction pile foundation for floating structures, namely group suction piles, was proposed to improve the shortcomings of conventional single suction piles. Small-scale model tests were performed to estimate the horizontal behavior of single suction piles and group suction piles with different pile spacing (2, 3 and 4 times the pile diameter). The horizontal behavior of group suction piles with different pile spacing was analyzed for various loading locations based on the model tests. For the given group pile configurations (a group pile having 9 component piles with a pile formation of 3 × 3), the horizontal resistance increased with increasing pile spacing. The maximum ultimate horizontal resistances were found at the loading locations of 50% of the embedded depth. Unlikely in the single suction pile case, the significantly maintained residual resistances were found for group suction piles. The residual resistances of group suction piles were at least higher than 40% of the corresponding ultimate horizontal resistances.
单桩与群桩水平阻力的试验比较
针对传统的单桩吸力桩存在的不足,本文提出了一种新型的浮式结构吸力桩基础——群吸力桩。对不同桩距(桩径2倍、3倍和4倍)下的单桩和群桩水平行为进行了小尺度模型试验。在模型试验的基础上,分析了不同桩距群吸桩在不同荷载位置下的水平行为。对于给定的群桩构型(一群桩有9根组份桩,桩形为3 × 3),水平阻力随桩间距的增大而增大。最大极限水平阻力出现在埋深50%的加载位置。在单个吸力桩的情况下,发现群吸力桩的残余阻力明显保持。群吸桩的残余阻力至少高于相应极限水平阻力的40%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信