Effect of glycaemic control on corneal parameters among type 2 diabetes mellitus

Vidyalakshmi Jayaraj, Premjit Bhakat, Jyothi Thomas, K. Rao
{"title":"Effect of glycaemic control on corneal parameters among type 2 diabetes mellitus","authors":"Vidyalakshmi Jayaraj, Premjit Bhakat, Jyothi Thomas, K. Rao","doi":"10.35119/myjo.v4i1.244","DOIUrl":null,"url":null,"abstract":"Purpose: To study the effect of glycaemic control as demonstrated by the change in HbA1c on corneal parameters among patients with type 2 diabetes mellitus (T2DM). Study design: Prospective study analysing corneal parameters among patients with T2DM along with fluctuations in HbA1c.Methods: A prospective, single-centre, cohort study was carried out on T2DM patients with HbA1c > 6.5% from Kasturba Hospital, Manipal, India. The subjects underwent a comprehensive eye examination. One-hundred and twenty-two subjects who fulfilled the inclusion criteria were analysed using the Huvitz 9000A to measure anterior corneal curvature followed by ultrasound pachymetry to measure central corneal thickness (CCT) at baseline and after 3 months. A simple linear regression was used to compare the mean corneal parameters, CCT and anterior corneal curvature, for each group with the mean HbA1c. The mean difference was considered statistically significant only if the value was p < 0.05.Results: We observed a significant difference between baseline and follow-up levels of HbA1c (t = 2.487; df = 53; p < 0.05). Simple linear regression analysis showed a positive correlation and revealed a mean increase in CCT of 1.893 μm (p < 0.001) and a mean increase in anterior corneal curvature of 0.069 D (p < 0.005) for every unit increase in HbA1c.Conclusions: The present study showed that changes in CCT and anterior corneal curvature occur with respect to changes in HbA1c level. Thus, careful attention is required in considering HbA1c status when performing comprehensive eye examinations in diabetic patients.","PeriodicalId":405983,"journal":{"name":"Malaysian Journal of Ophthalmology","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaysian Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35119/myjo.v4i1.244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To study the effect of glycaemic control as demonstrated by the change in HbA1c on corneal parameters among patients with type 2 diabetes mellitus (T2DM). Study design: Prospective study analysing corneal parameters among patients with T2DM along with fluctuations in HbA1c.Methods: A prospective, single-centre, cohort study was carried out on T2DM patients with HbA1c > 6.5% from Kasturba Hospital, Manipal, India. The subjects underwent a comprehensive eye examination. One-hundred and twenty-two subjects who fulfilled the inclusion criteria were analysed using the Huvitz 9000A to measure anterior corneal curvature followed by ultrasound pachymetry to measure central corneal thickness (CCT) at baseline and after 3 months. A simple linear regression was used to compare the mean corneal parameters, CCT and anterior corneal curvature, for each group with the mean HbA1c. The mean difference was considered statistically significant only if the value was p < 0.05.Results: We observed a significant difference between baseline and follow-up levels of HbA1c (t = 2.487; df = 53; p < 0.05). Simple linear regression analysis showed a positive correlation and revealed a mean increase in CCT of 1.893 μm (p < 0.001) and a mean increase in anterior corneal curvature of 0.069 D (p < 0.005) for every unit increase in HbA1c.Conclusions: The present study showed that changes in CCT and anterior corneal curvature occur with respect to changes in HbA1c level. Thus, careful attention is required in considering HbA1c status when performing comprehensive eye examinations in diabetic patients.
血糖控制对2型糖尿病患者角膜参数的影响
目的:探讨糖化血红蛋白(HbA1c)对2型糖尿病(T2DM)患者角膜参数变化的血糖控制效果。研究设计:前瞻性研究,分析T2DM患者角膜参数与HbA1c波动的关系。方法:对来自印度马尼帕尔Kasturba医院的HbA1c≤6.5%的2型糖尿病患者进行前瞻性、单中心、队列研究。受试者接受了全面的眼部检查。122名符合纳入标准的受试者在基线和3个月后分别使用Huvitz 9000A测量角膜前曲率和超声测厚仪测量角膜中央厚度(CCT)。采用简单的线性回归比较各组的平均角膜参数、CCT和角膜前曲率与平均HbA1c。只有当p < 0.05时,才认为平均差异有统计学意义。结果:我们观察到基线和随访HbA1c水平有显著差异(t = 2.487;Df = 53;P < 0.05)。简单线性回归分析显示,HbA1c每增加一个单位,CCT平均增加1.893 μm (p < 0.001),角膜前曲率平均增加0.069 D (p < 0.005)。结论:本研究表明,CCT和角膜前曲率的变化与HbA1c水平的变化有关。因此,在对糖尿病患者进行全面眼科检查时,应仔细考虑HbA1c状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信