{"title":"Sub-Bandage Pressure in the Canine Forelimb after Rigid Splint Application by Surgeons and Veterinary Students","authors":"M. Vitt, D. Wingert, M. Conzemius","doi":"10.1055/s-0039-1695749","DOIUrl":null,"url":null,"abstract":"Abstract Objective The aim of this study was to measure and compare sub-bandage pressures after a rigid splint was applied to the forelimb of a dog by surgeons and veterinary students. Animals One, adult, Labrador Retriever. Methods Sub-bandage pressure was measured at five locations on the limb of a dog using a previously validated pneumatic compression measurement system over a 4-hour period after splint application. All participants received the same instructions and the same dog was used for each splint application. Results Across time and location, mean sub-bandage pressures from the experienced group were significantly greater than those from the inexperienced group at all transducer locations and at all time points. People from the inexperienced group recorded the greatest range in sub-bandage pressures and had significantly higher-pressure differences across the five locations sub-bandage pressure was measured. Conclusions and Clinical Relevance Surgeons applied their splint bandages with approximately 50% greater pressure and 50% less variability between locations. The large range in sub-bandage pressures found may suggest that decreased and/or increased sub-bandage pressure may predispose to bandage complications.","PeriodicalId":443672,"journal":{"name":"VCOT Open","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"VCOT Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0039-1695749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract Objective The aim of this study was to measure and compare sub-bandage pressures after a rigid splint was applied to the forelimb of a dog by surgeons and veterinary students. Animals One, adult, Labrador Retriever. Methods Sub-bandage pressure was measured at five locations on the limb of a dog using a previously validated pneumatic compression measurement system over a 4-hour period after splint application. All participants received the same instructions and the same dog was used for each splint application. Results Across time and location, mean sub-bandage pressures from the experienced group were significantly greater than those from the inexperienced group at all transducer locations and at all time points. People from the inexperienced group recorded the greatest range in sub-bandage pressures and had significantly higher-pressure differences across the five locations sub-bandage pressure was measured. Conclusions and Clinical Relevance Surgeons applied their splint bandages with approximately 50% greater pressure and 50% less variability between locations. The large range in sub-bandage pressures found may suggest that decreased and/or increased sub-bandage pressure may predispose to bandage complications.