Investigation of Distribution Transformer Loss of Life in Electric Vehicles Parking Lot Integrated System

S. M. Bagher Sadati, M. Yazdani-Asrami, M. Shafie‐khah, G. Osório, J. Catalão
{"title":"Investigation of Distribution Transformer Loss of Life in Electric Vehicles Parking Lot Integrated System","authors":"S. M. Bagher Sadati, M. Yazdani-Asrami, M. Shafie‐khah, G. Osório, J. Catalão","doi":"10.1109/CPE-POWERENG48600.2020.9161684","DOIUrl":null,"url":null,"abstract":"Nowadays, the operation of the smart distribution system (SDS) is more complicated with the penetration of electric vehicles (EVs), due to EVs’ uncertainties as well as the capability of vehicle-to-grid (V2G). On the other hand, distribution transformers (DTs) which have to meet the demand of EVs are one of the essential components of SDS; indeed, their failure can lead to irreparable damage. The cause of most of these failures is overloading and high ambient temperature. The overloading increases the temperature of the various parts of the DTs, especially hot spot temperature (HST). Increasing this temperature reduces the nominal life of the DTs. With a high number of EVs in the future, and as a consequence high energy demand which has not been taken into account in proper operating program, it could lead to the overloading of DTs. So, in this paper, the loss of life (LOL) of a DT that feeds the residential loads and an EV parking lot (EV PL) is investigated. The maximization of the profit of the distribution system operator (DSO) is considered in two different parts i.e. with/without the appropriate operation coefficient (OC) of DT. Also, two different scenarios are applied i.e. charging mode (CM) of EVs and charging/discharging mode (CDM) of EVs. The results show that if the OC is not properly considered, the LOL of the transformers will be significantly high, implying a higher total ownership cost.","PeriodicalId":111104,"journal":{"name":"2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 14th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE-POWERENG48600.2020.9161684","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Nowadays, the operation of the smart distribution system (SDS) is more complicated with the penetration of electric vehicles (EVs), due to EVs’ uncertainties as well as the capability of vehicle-to-grid (V2G). On the other hand, distribution transformers (DTs) which have to meet the demand of EVs are one of the essential components of SDS; indeed, their failure can lead to irreparable damage. The cause of most of these failures is overloading and high ambient temperature. The overloading increases the temperature of the various parts of the DTs, especially hot spot temperature (HST). Increasing this temperature reduces the nominal life of the DTs. With a high number of EVs in the future, and as a consequence high energy demand which has not been taken into account in proper operating program, it could lead to the overloading of DTs. So, in this paper, the loss of life (LOL) of a DT that feeds the residential loads and an EV parking lot (EV PL) is investigated. The maximization of the profit of the distribution system operator (DSO) is considered in two different parts i.e. with/without the appropriate operation coefficient (OC) of DT. Also, two different scenarios are applied i.e. charging mode (CM) of EVs and charging/discharging mode (CDM) of EVs. The results show that if the OC is not properly considered, the LOL of the transformers will be significantly high, implying a higher total ownership cost.
电动汽车停车场综合系统中配电变压器寿命损耗的研究
目前,随着电动汽车的普及,由于电动汽车的不确定性以及车辆对电网的能力,智能配电系统的运行变得更加复杂。另一方面,满足电动汽车需求的配电变压器是SDS的重要组成部分之一;事实上,它们的失败可能导致无法弥补的损害。大多数故障的原因是过载和高环境温度。过载会导致dt各部件温度升高,特别是热点温度升高。增加这个温度会降低dt的标称寿命。随着未来电动汽车数量的增加,在正确的运行方案中没有考虑到高能源需求,这可能导致dt过载。因此,本文研究了为住宅负荷和电动汽车停车场供电的DT的生命损失(LOL)。分配系统运营商(DSO)的利润最大化从两个不同的方面来考虑,即有/没有适当的DT运行系数(OC)。此外,还应用了两种不同的场景,即电动汽车的充电模式(CM)和充电/放电模式(CDM)。结果表明,如果不适当考虑成本成本,变压器的LOL将会非常高,这意味着更高的总拥有成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信