Comparison of energy parameters of electric storage systems for DC and AC traction power supply systems

V. Nezevak
{"title":"Comparison of energy parameters of electric storage systems for DC and AC traction power supply systems","authors":"V. Nezevak","doi":"10.21780/2223-9731-2022-81-1-38-52","DOIUrl":null,"url":null,"abstract":"Introduction. The article discusses the energy parameters of electric power storage systems for DC and AC traction power supply systems. The purpose of the research is to evaluate the energy parameters of electric power storage systems located within the inter-substation zone boundaries of the AC traction power supply system at the 25 kV voltage.Materials and methods. The author used the methods of modeling, statistics and the experimental results processing. Moreover, the paper presented the parameter estimation of the energy accumulation system on the basis of the traction calculations for the AC rolling stock. In addition, the author made two variants of calculations — in the presence and the absence of the electric storage system. The researcher also made the simulation of the electric storage system for the voltage source connected to the sectioning post busbars.Results. Using the simulation modeling, the author presents active and reactive power graphs of the inter-substation zone boundaries in the active sectioning post operation conditions. Therefore, the article demonstrates the graph of the expected charge, the discharge depth calculations for the nominal energy capacity and the required charging features, which guarantee the charge restoration of the accumulation system to the initial level.Discussion and conclusion. The author offers the comparative assessment of the electric storage systems for the traction power supply with the DС voltage of 3 kV and the AC voltage of 25 kV. The research demonstrates the reducing potential of the nominal accumulation parameters.","PeriodicalId":242112,"journal":{"name":"Russian Railway Science","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Railway Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21780/2223-9731-2022-81-1-38-52","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction. The article discusses the energy parameters of electric power storage systems for DC and AC traction power supply systems. The purpose of the research is to evaluate the energy parameters of electric power storage systems located within the inter-substation zone boundaries of the AC traction power supply system at the 25 kV voltage.Materials and methods. The author used the methods of modeling, statistics and the experimental results processing. Moreover, the paper presented the parameter estimation of the energy accumulation system on the basis of the traction calculations for the AC rolling stock. In addition, the author made two variants of calculations — in the presence and the absence of the electric storage system. The researcher also made the simulation of the electric storage system for the voltage source connected to the sectioning post busbars.Results. Using the simulation modeling, the author presents active and reactive power graphs of the inter-substation zone boundaries in the active sectioning post operation conditions. Therefore, the article demonstrates the graph of the expected charge, the discharge depth calculations for the nominal energy capacity and the required charging features, which guarantee the charge restoration of the accumulation system to the initial level.Discussion and conclusion. The author offers the comparative assessment of the electric storage systems for the traction power supply with the DС voltage of 3 kV and the AC voltage of 25 kV. The research demonstrates the reducing potential of the nominal accumulation parameters.
直流与交流牵引供电系统储能系统能量参数的比较
介绍。讨论了直流和交流牵引供电系统中储能系统的能量参数。研究的目的是评估25 kV电压下交流牵引供电系统变电站间区边界内的电力存储系统的能量参数。材料和方法。采用了建模、统计和实验结果处理等方法。在交流机车车辆牵引计算的基础上,给出了能量积累系统的参数估计。此外,作者进行了两种不同的计算-在有和没有电力储存系统。研究人员还对连接在分段母线上的电压源蓄电系统进行了仿真。通过仿真建模,给出了有功断面后运行工况下变电站间区边界有功和无功曲线。因此,本文给出了期望电荷图、标称能量容量的放电深度计算和所需的充电特征,保证了蓄能系统的电荷恢复到初始水平。讨论与结论。本文对DС电压为3kv和交流电压为25kv的牵引电源蓄电系统进行了对比评价。研究表明,名义积累参数具有降低的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信