A Novel RLC Load Emulation for Anti-Islanding Test Bench for Inverter and Machine Based Distributed Generation

Narayanar K Nakul, S. Shan, L. Umanand
{"title":"A Novel RLC Load Emulation for Anti-Islanding Test Bench for Inverter and Machine Based Distributed Generation","authors":"Narayanar K Nakul, S. Shan, L. Umanand","doi":"10.1109/ECCE.2018.8557867","DOIUrl":null,"url":null,"abstract":"This paper presents a novel parallel RLC resonant load emulation technique for anti-islanding test. In an anti-islanding test setup, the load parameters R, L and C vary as they are dependent on the distributed generation (DG) rating. With the proposed emulation technique, the parameters R, L and C of the load can be controlled, while preserving the dynamic behaviour of the passive load, under all operating conditions. Two different current control methods for emulation are discussed. A two-level voltage source inverter (VSI) is used to emulate the RLC load. The results are verified using detailed time domain modelling in PSCAD/EMTDC for different type of DGs. The steady state performance of the proposed emulation technique is verified experimentally for different type of loads.","PeriodicalId":415217,"journal":{"name":"2018 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"255 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2018.8557867","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents a novel parallel RLC resonant load emulation technique for anti-islanding test. In an anti-islanding test setup, the load parameters R, L and C vary as they are dependent on the distributed generation (DG) rating. With the proposed emulation technique, the parameters R, L and C of the load can be controlled, while preserving the dynamic behaviour of the passive load, under all operating conditions. Two different current control methods for emulation are discussed. A two-level voltage source inverter (VSI) is used to emulate the RLC load. The results are verified using detailed time domain modelling in PSCAD/EMTDC for different type of DGs. The steady state performance of the proposed emulation technique is verified experimentally for different type of loads.
一种新型逆变机分布式发电抗孤岛试验台RLC负载仿真
提出了一种新型的并联RLC谐振负载仿真技术,用于抗孤岛试验。在防孤岛试验装置中,负载参数R、L和C随分布式发电(DG)额定值而变化。利用所提出的仿真技术,可以控制负载的参数R、L和C,同时保持被动负载在所有工作条件下的动态特性。讨论了两种不同的仿真电流控制方法。采用双电平电压源逆变器(VSI)模拟RLC负载。在PSCAD/EMTDC中对不同类型的dg进行了详细的时域建模,验证了结果。通过实验验证了该仿真技术在不同负载下的稳态性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信