An adaptive proportional resonant controller for single phase PV grid connected inverter based on band-pass filter technique

H. Khalfalla, S. Ethni, M. Al-Greer, V. Pickert, M. Armstrong, Van Thang Phan
{"title":"An adaptive proportional resonant controller for single phase PV grid connected inverter based on band-pass filter technique","authors":"H. Khalfalla, S. Ethni, M. Al-Greer, V. Pickert, M. Armstrong, Van Thang Phan","doi":"10.1109/CPE.2017.7915211","DOIUrl":null,"url":null,"abstract":"This paper presents an adaptive proportional resonant (PR) controller for single phase grid connected inverter that adapts its control parameters to grid impedance variations. Forth order band bass filter is designed and then integrated with the adaptive scheme for on-line detection of any variations in the resonance frequency. The estimated frequency is then processed by statistical signal processing operation to identify the variations in the grid impedance. For the on-line tuning of the PR parameters, a look-up table technique is utilized and its parameters are linked with the estimated impedance values. Simulation results based on MATLAB environment clearly verify the effectiveness of the proposed control scheme for 2 kW grid connected inverter system.","PeriodicalId":259750,"journal":{"name":"2017 11th IEEE International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 11th IEEE International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2017.7915211","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

This paper presents an adaptive proportional resonant (PR) controller for single phase grid connected inverter that adapts its control parameters to grid impedance variations. Forth order band bass filter is designed and then integrated with the adaptive scheme for on-line detection of any variations in the resonance frequency. The estimated frequency is then processed by statistical signal processing operation to identify the variations in the grid impedance. For the on-line tuning of the PR parameters, a look-up table technique is utilized and its parameters are linked with the estimated impedance values. Simulation results based on MATLAB environment clearly verify the effectiveness of the proposed control scheme for 2 kW grid connected inverter system.
基于带通滤波技术的单相光伏并网逆变器自适应比例谐振控制器
提出了一种单相并网逆变器比例谐振自适应控制器,该控制器可以根据电网阻抗的变化来调整控制参数。设计了四阶带低音滤波器,并将其与自适应方案相结合,实现了对谐振频率变化的在线检测。然后通过统计信号处理操作对估计的频率进行处理,以识别网格阻抗的变化。对于阻抗参数的在线调整,采用了查找表技术,并将其参数与估计的阻抗值联系起来。基于MATLAB环境的仿真结果清楚地验证了所提控制方案对2kw并网逆变器系统的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信