Inverse definite minimum time overcurrent relay coordination using Computer Aided Protection Engineering

M. Hairi, K. Alias, M. Aras, M. F. Basar, S. Fah
{"title":"Inverse definite minimum time overcurrent relay coordination using Computer Aided Protection Engineering","authors":"M. Hairi, K. Alias, M. Aras, M. F. Basar, S. Fah","doi":"10.1109/PEOCO.2010.5559184","DOIUrl":null,"url":null,"abstract":"Protective relays, especially IDMT (Inverse Definite Minimum Time) overcurrent relays is crucial in the power system protection. It is important that in any case of the system abnormalities or faults, the IDMT overcurrent must be capable to isolate only the faulty component from the healthy system. This paper presents the study on the coordination of the IDMT relay in the tested network whereby the existing setting of TMS (Time Multiple Setting) and PS (Plug Setting) currently adopted is studied to validate the setting, hence, to proposed the recommendation for the new setting for any miscoordination. This paper was developed to cater the coordination study in the power system network by means of the comprehensive computer based tool, Computer Aided Protection Engineering (CAPE) devised for various studies, such as coordination study. The tests result of the network was studied, analyzed and discussed.","PeriodicalId":379868,"journal":{"name":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 4th International Power Engineering and Optimization Conference (PEOCO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEOCO.2010.5559184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Protective relays, especially IDMT (Inverse Definite Minimum Time) overcurrent relays is crucial in the power system protection. It is important that in any case of the system abnormalities or faults, the IDMT overcurrent must be capable to isolate only the faulty component from the healthy system. This paper presents the study on the coordination of the IDMT relay in the tested network whereby the existing setting of TMS (Time Multiple Setting) and PS (Plug Setting) currently adopted is studied to validate the setting, hence, to proposed the recommendation for the new setting for any miscoordination. This paper was developed to cater the coordination study in the power system network by means of the comprehensive computer based tool, Computer Aided Protection Engineering (CAPE) devised for various studies, such as coordination study. The tests result of the network was studied, analyzed and discussed.
计算机辅助保护工程的逆定最小时间过流继电器协调
继电保护,特别是IDMT过流继电器在电力系统保护中起着至关重要的作用。重要的是,在任何系统异常或故障的情况下,IDMT过电流必须能够仅将故障组件与健康系统隔离开来。本文对被测网络中IDMT继电器的协调进行了研究,研究了目前采用的TMS (Time Multiple setting)和PS (Plug setting)的现有整定,对整定进行了验证,并对任何不协调的情况提出了新的整定建议。本文是利用基于计算机的综合工具——计算机辅助保护工程(CAPE),为协调研究等各种研究而设计的,以满足电网协调研究的需要而开发的。对网络的测试结果进行了研究、分析和讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信