{"title":"Impact of high PV penetration on voltage regulation in electrical distribution systems","authors":"G. K. Ari, Y. Baghzouz","doi":"10.1109/ICCEP.2011.6036386","DOIUrl":null,"url":null,"abstract":"Cloud-induced transients induced in photovoltaic (PV) power are considered as a potential barrier to further expansion when the penetration of this renewable generation resource reaches a high level in distribution systems. Such transients can cause voltage flicker or excessive operation of the voltage regulating equipment. This article studies these effects on part of a local distribution substation. Actual transformer load and solar irradiance data based on 1-minute interval are used to simulate the impact of 20% PV penetration on the feeder voltage during a time period that covers both clear and cloudy skies. Based on some specified conditions, the simulations indicate that voltage flicker is not a concern, but the tap changer operates excessively even when using a 5-minute time delay.","PeriodicalId":403158,"journal":{"name":"2011 International Conference on Clean Electrical Power (ICCEP)","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"109","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Clean Electrical Power (ICCEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEP.2011.6036386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 109
Abstract
Cloud-induced transients induced in photovoltaic (PV) power are considered as a potential barrier to further expansion when the penetration of this renewable generation resource reaches a high level in distribution systems. Such transients can cause voltage flicker or excessive operation of the voltage regulating equipment. This article studies these effects on part of a local distribution substation. Actual transformer load and solar irradiance data based on 1-minute interval are used to simulate the impact of 20% PV penetration on the feeder voltage during a time period that covers both clear and cloudy skies. Based on some specified conditions, the simulations indicate that voltage flicker is not a concern, but the tap changer operates excessively even when using a 5-minute time delay.