{"title":"Skeleton-based continuous extrinsic calibration of multiple RGB-D kinect cameras","authors":"Kevin Desai, B. Prabhakaran, S. Raghuraman","doi":"10.1145/3204949.3204969","DOIUrl":null,"url":null,"abstract":"Applications involving 3D scanning and reconstruction & 3D Tele-immersion provide an immersive experience by capturing a scene using multiple RGB-D cameras, such as Kinect. Prior knowledge of intrinsic calibration of each of the cameras, and extrinsic calibration between cameras, is essential to reconstruct the captured data. The intrinsic calibration for a given camera rarely ever changes, so only needs to be estimated once. However, the extrinsic calibration between cameras can change, even with a small nudge to the camera. Calibration accuracy depends on sensor noise, features used, sampling method, etc., resulting in the need for iterative calibration to achieve good calibration. In this paper, we introduce a skeleton based approach to calibrate multiple RGB-D Kinect cameras in a closed setup, automatically without any intervention, within a few seconds. The method uses only the person present in the scene to calibrate, removing the need for manually inserting, detecting and extracting other objects like plane, checker-board, sphere, etc. 3D joints of the extracted skeleton are used as correspondence points between cameras, after undergoing accuracy and orientation checks. Temporal, spatial, and motion constraints are applied during the point selection strategy. Our calibration error checking is inexpensive in terms of computational cost and time and hence is continuously run in the background. Automatic re-calibration of the cameras can be performed when the calibration error goes beyond a threshold due to any possible camera movement. Evaluations show that the method can provide fast, accurate and continuous calibration, as long as a human is moving around in the captured scene.","PeriodicalId":141196,"journal":{"name":"Proceedings of the 9th ACM Multimedia Systems Conference","volume":"354 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 9th ACM Multimedia Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3204949.3204969","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Applications involving 3D scanning and reconstruction & 3D Tele-immersion provide an immersive experience by capturing a scene using multiple RGB-D cameras, such as Kinect. Prior knowledge of intrinsic calibration of each of the cameras, and extrinsic calibration between cameras, is essential to reconstruct the captured data. The intrinsic calibration for a given camera rarely ever changes, so only needs to be estimated once. However, the extrinsic calibration between cameras can change, even with a small nudge to the camera. Calibration accuracy depends on sensor noise, features used, sampling method, etc., resulting in the need for iterative calibration to achieve good calibration. In this paper, we introduce a skeleton based approach to calibrate multiple RGB-D Kinect cameras in a closed setup, automatically without any intervention, within a few seconds. The method uses only the person present in the scene to calibrate, removing the need for manually inserting, detecting and extracting other objects like plane, checker-board, sphere, etc. 3D joints of the extracted skeleton are used as correspondence points between cameras, after undergoing accuracy and orientation checks. Temporal, spatial, and motion constraints are applied during the point selection strategy. Our calibration error checking is inexpensive in terms of computational cost and time and hence is continuously run in the background. Automatic re-calibration of the cameras can be performed when the calibration error goes beyond a threshold due to any possible camera movement. Evaluations show that the method can provide fast, accurate and continuous calibration, as long as a human is moving around in the captured scene.
基于骨骼的多个RGB-D kinect摄像头的连续外部校准
涉及3D扫描和重建和3D远程沉浸的应用程序通过使用多个RGB-D相机(如Kinect)捕捉场景,提供身临其境的体验。对于重建捕获的数据,每个摄像机的固有校准和摄像机之间的外部校准的先验知识是必不可少的。给定相机的固有校准很少改变,所以只需要估计一次。然而,相机之间的外部校准可能会改变,即使对相机进行轻微的推动。校准精度取决于传感器噪声、使用的特征、采样方法等,导致需要迭代校准才能实现良好的校准。在本文中,我们介绍了一种基于骨架的方法来在封闭设置中自动校准多个RGB-D Kinect摄像机,无需任何干预,只需几秒钟。该方法仅使用场景中存在的人进行校准,无需手动插入,检测和提取平面,棋盘,球体等其他物体。提取的骨架的3D关节作为相机之间的对应点,经过精度和方向检查。在点选择策略中应用时间、空间和运动约束。我们的校准误差检查在计算成本和时间方面是廉价的,因此在后台连续运行。当由于任何可能的相机移动而导致校准误差超过阈值时,可以执行相机的自动重新校准。评估表明,该方法可以提供快速、准确和连续的校准,只要一个人在捕获的场景中走动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信