{"title":"Reactive power compensation for spot welding machine using thyristor switched capacitor","authors":"A. Kallaste, L. Kutt, V. Bolgov, K. Janson","doi":"10.1109/PQ.2008.4653768","DOIUrl":null,"url":null,"abstract":"High-power industrial spot-welding machines make use of transformers that have very high reactive power consumption. Simple reactive power compensation schemes cannot be used however, because of the cyclic nature of the spot welding transformer operating. This paper describes the development of a simple reactive power compensator solution for the spot-welding machines. Focus is also put on the transformer saturation and current transients that can emerge from deployment of such reactive power compensation methods.","PeriodicalId":429968,"journal":{"name":"2008 Power Quality and Supply Reliability Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Power Quality and Supply Reliability Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQ.2008.4653768","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

High-power industrial spot-welding machines make use of transformers that have very high reactive power consumption. Simple reactive power compensation schemes cannot be used however, because of the cyclic nature of the spot welding transformer operating. This paper describes the development of a simple reactive power compensator solution for the spot-welding machines. Focus is also put on the transformer saturation and current transients that can emerge from deployment of such reactive power compensation methods.
晶闸管开关电容点焊机无功补偿
大功率工业点焊机使用的变压器无功功率消耗非常高。然而,由于点焊变压器运行的周期性,简单的无功补偿方案不能使用。本文介绍了一种简单的点焊机无功补偿方案的研制。重点还放在变压器饱和和电流暂态可能出现的部署这种无功补偿方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信