Adapter and method for improving the LISN input impedance measurement accuracy

F. Ziadé, M. Ouameur, D. Bélières, A. Poletaeff, D. Allal, M. Kokalj, B. Pinter
{"title":"Adapter and method for improving the LISN input impedance measurement accuracy","authors":"F. Ziadé, M. Ouameur, D. Bélières, A. Poletaeff, D. Allal, M. Kokalj, B. Pinter","doi":"10.1109/ISEMC.2015.7256350","DOIUrl":null,"url":null,"abstract":"The Line Impedance Stabilization Network (LISN) is mostly used in electromagnetic compatibility for conducted and radiated radio-frequency emission and susceptibility tests. The input impedance is one of the most important parameters in LISN calibration. To measure the input impedance, an adapter is required to connect the Vector Network Analyzer (VNA) to the Equipment Under Test (EUT) port of the LISN. For test laboratories, it is of best interest to perform this calibration with high accuracy. Until now the impact of the adapter has not been clearly demonstrated theoretically. We present the design of an adapter and its associated modelling, a method for removing its impact from the measurement, the theoretical error on magnitude and phase input impedance.","PeriodicalId":412708,"journal":{"name":"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Electromagnetic Compatibility (EMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2015.7256350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The Line Impedance Stabilization Network (LISN) is mostly used in electromagnetic compatibility for conducted and radiated radio-frequency emission and susceptibility tests. The input impedance is one of the most important parameters in LISN calibration. To measure the input impedance, an adapter is required to connect the Vector Network Analyzer (VNA) to the Equipment Under Test (EUT) port of the LISN. For test laboratories, it is of best interest to perform this calibration with high accuracy. Until now the impact of the adapter has not been clearly demonstrated theoretically. We present the design of an adapter and its associated modelling, a method for removing its impact from the measurement, the theoretical error on magnitude and phase input impedance.
用于提高LISN输入阻抗测量精度的适配器和方法
线路阻抗稳定网络(LISN)主要用于电磁兼容性的传导和辐射射频发射和敏感性测试。输入阻抗是LISN校准中最重要的参数之一。为了测量输入阻抗,需要一个适配器将矢量网络分析仪(VNA)连接到LISN的被测设备(EUT)端口。对于测试实验室来说,以高精度执行此校准是最感兴趣的。到目前为止,适配器的影响还没有从理论上得到明确的证明。我们提出了一种适配器的设计及其相关建模,一种消除其对测量影响的方法,对幅度和相位输入阻抗的理论误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信