Novel folded pendulum residual seism accelerometer for the Virgo gravitational wave observatory: parasitic resonance mode characterisation

Harun Džafić
{"title":"Novel folded pendulum residual seism accelerometer for the Virgo gravitational wave observatory: parasitic resonance mode characterisation","authors":"Harun Džafić","doi":"10.25609/SURE.V4.2836","DOIUrl":null,"url":null,"abstract":"Optical components of a gravitational wave (GW) detector must both actively and passively be isolated from microseisms to be able to detect GWs. Active attenuation is achieved by making use of accelerometers within seismic isolation systems. Herein, a characterisation of the internal leg mode resonances of an improved design Folded Pendulum accelerometer, present at the Virgo GW observatory, is being discussed. We model internal leg mode resonances of the accelerometer using Finite Element Method analysis and we experimentally confirm the horizontal in-plane and tilt resonances below 1 kHz, by use of a shadow sensing application combined with Bode plots.","PeriodicalId":106615,"journal":{"name":"Student Undergraduate Research E-journal","volume":"387 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Student Undergraduate Research E-journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25609/SURE.V4.2836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Optical components of a gravitational wave (GW) detector must both actively and passively be isolated from microseisms to be able to detect GWs. Active attenuation is achieved by making use of accelerometers within seismic isolation systems. Herein, a characterisation of the internal leg mode resonances of an improved design Folded Pendulum accelerometer, present at the Virgo GW observatory, is being discussed. We model internal leg mode resonances of the accelerometer using Finite Element Method analysis and we experimentally confirm the horizontal in-plane and tilt resonances below 1 kHz, by use of a shadow sensing application combined with Bode plots.
用于处女座引力波天文台的新型折叠摆剩余地震加速度计:寄生共振模式表征
引力波探测器的光学元件必须主动和被动地与微震隔离,才能探测到引力波。主动衰减是通过在隔震系统中使用加速度计实现的。本文讨论了室女座GW天文台改进设计的折叠摆加速度计的内部腿模共振特性。我们使用有限元法分析加速度计的内部腿模式共振,并通过使用阴影传感应用程序结合波德图,实验证实了1 kHz以下的水平面内和倾斜共振。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信