Kriangkrai Maneerat, Krisada Chinda, Charuwalee Suwatthikul, L. Klinkusoom, L. Kovavisaruch, K. Kaemarungsi
{"title":"A Study of Reference Node Placement based on 4- quadrant Node Selection in Ultra Wideband Indoor Positioning System","authors":"Kriangkrai Maneerat, Krisada Chinda, Charuwalee Suwatthikul, L. Klinkusoom, L. Kovavisaruch, K. Kaemarungsi","doi":"10.1109/ITNAC50341.2020.9315162","DOIUrl":null,"url":null,"abstract":"This paper investigated the impact of the reference node (RN) placement on the localization performance of Ultra wideband (UWB) indoor positioning system. Different RN- placement patterns based on 4-quadrant node selection strategy were experimented. The accuracy performance of UWB indoor positioning systems was evaluated with 3D trilateration algorithm. Experimental results showed that the RN placement with a crossing pattern (Pattern A) provided the highest location accuracy performance in which an average error distance was less than 0.24 m. Moreover, we found that the RN placement with a sloping pattern (Pattern B) could cause the accuracy performance degradation up to 66%. In particular, the positioning error of y- and z-coordinate of the tag placed in the middle for Pattern B was almost 1 m.","PeriodicalId":131639,"journal":{"name":"2020 30th International Telecommunication Networks and Applications Conference (ITNAC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 30th International Telecommunication Networks and Applications Conference (ITNAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITNAC50341.2020.9315162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
This paper investigated the impact of the reference node (RN) placement on the localization performance of Ultra wideband (UWB) indoor positioning system. Different RN- placement patterns based on 4-quadrant node selection strategy were experimented. The accuracy performance of UWB indoor positioning systems was evaluated with 3D trilateration algorithm. Experimental results showed that the RN placement with a crossing pattern (Pattern A) provided the highest location accuracy performance in which an average error distance was less than 0.24 m. Moreover, we found that the RN placement with a sloping pattern (Pattern B) could cause the accuracy performance degradation up to 66%. In particular, the positioning error of y- and z-coordinate of the tag placed in the middle for Pattern B was almost 1 m.