The design of ultra low noise CMOS transimpedance amplifier for biosensing applications

Kavyashree Puttananjegowda, Majdi M. Ababneh, Sylvia W. Thomas
{"title":"The design of ultra low noise CMOS transimpedance amplifier for biosensing applications","authors":"Kavyashree Puttananjegowda, Majdi M. Ababneh, Sylvia W. Thomas","doi":"10.1109/UEMCON.2017.8248971","DOIUrl":null,"url":null,"abstract":"This paper presents, a low-noise, low-power transimpedance amplifier (TIA) for amperiometric based blood glucose monitoring system for wearable devices. The proposed cascode common source multi-stage transimpedance amplifier circuit is implemented in a 180nm CMOS process. The TIA shows a transimpedance gain of 145MΩ and input referred current noise is 27.4fA/√Hz at 50kHz. When the input current is 5nA and the total power consumption is 110uW from 1V supply.","PeriodicalId":403890,"journal":{"name":"2017 IEEE 8th Annual Ubiquitous Computing, Electronics and Mobile Communication Conference (UEMCON)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 8th Annual Ubiquitous Computing, Electronics and Mobile Communication Conference (UEMCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UEMCON.2017.8248971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper presents, a low-noise, low-power transimpedance amplifier (TIA) for amperiometric based blood glucose monitoring system for wearable devices. The proposed cascode common source multi-stage transimpedance amplifier circuit is implemented in a 180nm CMOS process. The TIA shows a transimpedance gain of 145MΩ and input referred current noise is 27.4fA/√Hz at 50kHz. When the input current is 5nA and the total power consumption is 110uW from 1V supply.
生物传感用超低噪声CMOS跨阻放大器的设计
本文提出了一种低噪声、低功耗的跨阻抗放大器(TIA),用于基于电流计的可穿戴设备血糖监测系统。所提出的级联码共源多级跨阻放大电路在180nm CMOS工艺上实现。TIA显示的跨阻增益为145MΩ,在50kHz时输入参考电流噪声为27.4fA/√Hz。当输入电流为5nA, 1V电源总功耗为110uW时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信