Development of a Wrist Sphygmomanometer with an Active Soft Mechanism

Nobuaki Yoshimura, Yasutaka Nishioka, T. Yasuda, M. Yamano, Minoru Taniguchi, Chisato Uesaka, Tuyoshi Hamaguchi, Masao Shimizu
{"title":"Development of a Wrist Sphygmomanometer with an Active Soft Mechanism","authors":"Nobuaki Yoshimura, Yasutaka Nishioka, T. Yasuda, M. Yamano, Minoru Taniguchi, Chisato Uesaka, Tuyoshi Hamaguchi, Masao Shimizu","doi":"10.1109/ICMA52036.2021.9512680","DOIUrl":null,"url":null,"abstract":"In recent years, with the aging of the population, home health care using a home blood pressure monitor has been emphasized. I think that more measurements during the day are needed for people to observe blood pressure more accurately and use it to manage their physical condition. Therefore, in order to reduce the number of measurement procedures as much as possible, the purpose is to reduce the number of measurement procedures in a compact size by performing the measurement only by placing the wrist from above. In this study, we manufactured a device that restrains, compresses, and measures the wrist using a soft actuator made of film. We designed three types of triangular prism type soft actuators with active mechanisms, and constructed a drive sequence using solenoid valves. A pulsation measurement experiment was conducted using the manufactured device, and I was able to measure accurate pulsation by myself.","PeriodicalId":339025,"journal":{"name":"2021 IEEE International Conference on Mechatronics and Automation (ICMA)","volume":"103 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Conference on Mechatronics and Automation (ICMA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMA52036.2021.9512680","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In recent years, with the aging of the population, home health care using a home blood pressure monitor has been emphasized. I think that more measurements during the day are needed for people to observe blood pressure more accurately and use it to manage their physical condition. Therefore, in order to reduce the number of measurement procedures as much as possible, the purpose is to reduce the number of measurement procedures in a compact size by performing the measurement only by placing the wrist from above. In this study, we manufactured a device that restrains, compresses, and measures the wrist using a soft actuator made of film. We designed three types of triangular prism type soft actuators with active mechanisms, and constructed a drive sequence using solenoid valves. A pulsation measurement experiment was conducted using the manufactured device, and I was able to measure accurate pulsation by myself.
带主动软机构手腕血压计的研制
近年来,随着人口老龄化,使用家庭血压计的家庭保健受到重视。我认为人们需要在白天进行更多的测量,以更准确地观察血压,并利用它来管理自己的身体状况。因此,为了尽可能减少测量程序的数量,其目的是通过仅将手腕从上方放置进行测量,从而在紧凑的尺寸中减少测量程序的数量。在这项研究中,我们制造了一种装置,使用由薄膜制成的软致动器来约束、压缩和测量手腕。设计了三种带主动机构的三角棱镜型软执行器,并利用电磁阀构建了驱动序列。利用所研制的装置进行了脉动测量实验,实现了对脉动的精确测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信