Yuzhe Liu, Lian Chen, Futian Liang, Feng Li, G. Jin
{"title":"High counting-rate data acquisition system for the applications of PGNAA","authors":"Yuzhe Liu, Lian Chen, Futian Liang, Feng Li, G. Jin","doi":"10.1109/RTC.2016.7543089","DOIUrl":null,"url":null,"abstract":"The prompt γ-ray neutron activation analysis (referred PGNAA) technology is a use of the strong penetrating power of neutron and γ-ray, which can get the whole information of the elements inside a thick material. Therefore, the PGNAA technology has become the best choice to meet the needs of detecting the composition of industrial materials. This paper presents a data acquisition scheme for the physical targets of PGNAA, which has a high pass rate, high SNR and can analyze and process a large number of pulses which the detector outputs. This system is designed to rapidly analyze the composition and content of the industrial materials in real-time. Since we have to dynamically analyze the moving materials, the expected time for a measurement can not exceed 120s, The average counting rate is expected to reach more than 500kc/s.","PeriodicalId":383702,"journal":{"name":"2016 IEEE-NPSS Real Time Conference (RT)","volume":"307 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE-NPSS Real Time Conference (RT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTC.2016.7543089","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The prompt γ-ray neutron activation analysis (referred PGNAA) technology is a use of the strong penetrating power of neutron and γ-ray, which can get the whole information of the elements inside a thick material. Therefore, the PGNAA technology has become the best choice to meet the needs of detecting the composition of industrial materials. This paper presents a data acquisition scheme for the physical targets of PGNAA, which has a high pass rate, high SNR and can analyze and process a large number of pulses which the detector outputs. This system is designed to rapidly analyze the composition and content of the industrial materials in real-time. Since we have to dynamically analyze the moving materials, the expected time for a measurement can not exceed 120s, The average counting rate is expected to reach more than 500kc/s.