{"title":"Performance Comparison of Air-Cooled and Water-Cooled Air-Conditioners Applied in Residential Buildings","authors":"C. Hua, D. Qianqian, Lee Wl","doi":"10.1115/1.802908.paper85","DOIUrl":null,"url":null,"abstract":"The objectives of this study are to evaluate the water-cooled technology for residential cooling applications. A split air-cooled air-conditioner and a prototype water-cooled air-conditioner were set up for experimental test at different indoor and outdoor conditions. The units’performance and power consumption were calculated as baselines for comparison.","PeriodicalId":198953,"journal":{"name":"Building Energy & Environment","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Energy & Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.802908.paper85","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The objectives of this study are to evaluate the water-cooled technology for residential cooling applications. A split air-cooled air-conditioner and a prototype water-cooled air-conditioner were set up for experimental test at different indoor and outdoor conditions. The units’performance and power consumption were calculated as baselines for comparison.