{"title":"Fluorescent lamp cold environment performance improvement","authors":"M. Graovac, F. Dawson, M. Fila, D. E. Cormack","doi":"10.1109/IAS.1998.730116","DOIUrl":null,"url":null,"abstract":"Three approaches to improving the efficacy and start-up time of commercially available cold cathode fluorescent lamps under cold ambient conditions are evaluated in this paper: heating the tube on one side; heating the tube on two sides; heating the circumference of the outer tube. The internal power density generated by ion bombardment of the cathode and collisions in the plasma is indirectly obtained by matching simulated axial wall temperatures with those obtained by experiment at room temperature. The estimated power density is used to evaluate the temporal evolution of the axial surface wall temperature under different ambient conditions immediately after a cold start. All simulation results have been obtained using PHOENICS, a computational fluid flow program. Experiments have shown a good correlation between the time taken for the light output to reach an acceptable value and the time taken for the inner tube cold spot to reach a temperature of 0/spl deg/C. These results have been used to estimate heating time for different heater geometries and heater powers. The study shows that the conduction of heat to the outer glass envelope is the limiting process that controls the start-up time. Modest improvement in start-up time can be achieved by increasing heating power or by moving the heater to the side of the lamp. However, only a heater which entirely surrounds the lamp is capable of substantially decreasing the start-up time.","PeriodicalId":321042,"journal":{"name":"Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1998.730116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Three approaches to improving the efficacy and start-up time of commercially available cold cathode fluorescent lamps under cold ambient conditions are evaluated in this paper: heating the tube on one side; heating the tube on two sides; heating the circumference of the outer tube. The internal power density generated by ion bombardment of the cathode and collisions in the plasma is indirectly obtained by matching simulated axial wall temperatures with those obtained by experiment at room temperature. The estimated power density is used to evaluate the temporal evolution of the axial surface wall temperature under different ambient conditions immediately after a cold start. All simulation results have been obtained using PHOENICS, a computational fluid flow program. Experiments have shown a good correlation between the time taken for the light output to reach an acceptable value and the time taken for the inner tube cold spot to reach a temperature of 0/spl deg/C. These results have been used to estimate heating time for different heater geometries and heater powers. The study shows that the conduction of heat to the outer glass envelope is the limiting process that controls the start-up time. Modest improvement in start-up time can be achieved by increasing heating power or by moving the heater to the side of the lamp. However, only a heater which entirely surrounds the lamp is capable of substantially decreasing the start-up time.
荧光灯冷环境性能改善
本文评价了在冷环境条件下提高市售冷阴极荧光灯的效率和启动时间的三种方法:加热灯管的一侧;加热管的两侧;加热外管的圆周。通过将模拟的轴壁温度与室温下的实验温度进行匹配,间接得到了阴极离子轰击和等离子体碰撞产生的内部功率密度。利用估计的功率密度来评估冷启动后不同环境条件下轴向表面壁温度的时间演变。所有的模拟结果都是用PHOENICS计算流体流动程序得到的。实验表明,光输出达到可接受值所需的时间与内管冷点达到0/spl℃温度所需的时间之间具有良好的相关性。这些结果已用于估计加热时间为不同的加热器几何形状和加热器功率。研究表明,热传导到外层玻璃包络层是控制启动时间的限制过程。适度改善启动时间可以通过增加加热功率或通过将加热器移动到灯的一侧来实现。然而,只有完全环绕灯的加热器才能大大缩短启动时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书