A COMPARATIVE STUDY IN PENETRATION DEPTH OF RESIN-BASED MATERIALS INTO WHITE SPOT LESION

M. Mohamed, Abdallah A. Abdalhady, K. Noaman
{"title":"A COMPARATIVE STUDY IN PENETRATION DEPTH OF RESIN-BASED MATERIALS INTO WHITE SPOT LESION","authors":"M. Mohamed, Abdallah A. Abdalhady, K. Noaman","doi":"10.47672/ejhs.515","DOIUrl":null,"url":null,"abstract":"Purpose: This study conducts an in vitro comparison of the depth of penetration of a resin infiltrant material (Icon), a two-step self-etch resin-based material (OptiBondTM XTR), and a solvent-free self-etch resin-based material (Bond-1SF) into white spot lesions (WSLs).Methodology: Through an in vitro clinical trial, a total of 60 human posterior teeth, free from caries, were collected. The buccal and lingual surfaces of each tooth were marked, resulting in a total of 120 samples of surfaces, which represented the operational sample size. The samples were randomly divided into four equal main groups (n = 30) according to the materials used. Group 1 (M1) was the control group. Group 2 (M2) was restored using Icon, Group 3 (M3) using OptiBondTM XTR, and Group 4 (M4) using Bond-1SF. Each group was divided into two equal groups (n = 15) according to the surface treatment, and the first group (W1) was subjected to surface treatment but the second group (W2) was not. The resin penetration depth was observed using confocal laser scanning microscopy.Findings: The highest penetration depth was recorded for Group 2 with surface treatment (M2W1), and the lowest was recorded for Group 4 without surface treatment (M4W2). An analysis of variance test revealed a statistically significant difference in the penetration depth of tested materials (p < 0.05).Conclusion: Icon shows the best penetration depth value in relation to WSLs, whereas Bond-1SF shows the worst. Surface treatment has a positive effect on the penetration depth of the resin-based materials.","PeriodicalId":224837,"journal":{"name":"European Journal of Health Sciences","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47672/ejhs.515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: This study conducts an in vitro comparison of the depth of penetration of a resin infiltrant material (Icon), a two-step self-etch resin-based material (OptiBondTM XTR), and a solvent-free self-etch resin-based material (Bond-1SF) into white spot lesions (WSLs).Methodology: Through an in vitro clinical trial, a total of 60 human posterior teeth, free from caries, were collected. The buccal and lingual surfaces of each tooth were marked, resulting in a total of 120 samples of surfaces, which represented the operational sample size. The samples were randomly divided into four equal main groups (n = 30) according to the materials used. Group 1 (M1) was the control group. Group 2 (M2) was restored using Icon, Group 3 (M3) using OptiBondTM XTR, and Group 4 (M4) using Bond-1SF. Each group was divided into two equal groups (n = 15) according to the surface treatment, and the first group (W1) was subjected to surface treatment but the second group (W2) was not. The resin penetration depth was observed using confocal laser scanning microscopy.Findings: The highest penetration depth was recorded for Group 2 with surface treatment (M2W1), and the lowest was recorded for Group 4 without surface treatment (M4W2). An analysis of variance test revealed a statistically significant difference in the penetration depth of tested materials (p < 0.05).Conclusion: Icon shows the best penetration depth value in relation to WSLs, whereas Bond-1SF shows the worst. Surface treatment has a positive effect on the penetration depth of the resin-based materials.
树脂基材料对白斑病变穿透深度的比较研究
目的:本研究对树脂浸润材料(Icon)、两步自蚀刻树脂基材料(OptiBondTM XTR)和无溶剂自蚀刻树脂基材料(Bond-1SF)在白斑病变(WSLs)中的渗透深度进行体外比较。方法:通过体外临床试验,收集无龋的人后牙60颗。标记每颗牙齿的颊面和舌面,总共得到120个表面样本,这代表了操作样本量。根据使用的材料,将样本随机分为4个相等的主要组(n = 30)。第一组(M1)为对照组。2组(M2)采用Icon修复,3组(M3)采用OptiBondTM XTR修复,4组(M4)采用Bond-1SF修复。每组按表面处理情况分为两组(n = 15),第一组(W1)进行表面处理,第二组(W2)不进行表面处理。用激光共聚焦扫描显微镜观察树脂的穿透深度。结果:经表面处理组2的穿透深度最高(M2W1),未经表面处理组4的穿透深度最低(M4W2)。方差检验分析显示,被测材料的穿透深度差异有统计学意义(p < 0.05)。结论:与WSLs相关,Icon的穿透深度值最好,Bond-1SF最差。表面处理对树脂基材料的渗透深度有积极的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信