{"title":"Detecting Relative Changes in Circulating Blood Volume using Ultrasound and Simulation","authors":"J. R. Anaraki, Saeed Samet, M. Shehata, K. Aubrey-Bassler, E. Karami, Saba Samet, Andrew J. Smith","doi":"10.1109/CBMS.2019.00063","DOIUrl":null,"url":null,"abstract":"Portable ultrasound is increasingly used to assess jugular venous pressure (JVP) to approximate volume status in patients with congestive heart failure (CHF). Traditionally, increases in jugular venous pressure height signify increasing circulating blood volume. Emerging evidence, suggests that JVP correlates well with sonographic images of the internal jugular vein (IJV). This paper represents a preliminary investigation on the ability of cross-sectional area (CSA) of the IJV to measure relative changes in circulating blood volume. Fourteen healthy subjects had serial transverse ultrasound videos of their IJV captured while lying at five angles designed to simulate relative changes in blood volume. Ultrasound videos of the IJV were both manually and semi-automatically segmented, the CSA was measured, outliers were detected and removed, and Rotation Forest classifier was used to classify the data. By limiting the number of classes from five to three and removing outliers the accuracies improved from 59.50% to 91.05% and 62.74% to 91.89% for manual and semi-automatic segmentation, respectively. This pilot demonstrated that serial measurement of the CSA of the IJV in combination with machine learning techniques represents a viable opportunity to monitor changes in circulating blood volume in healthy subjects, setting the stage for a trial monitoring of patients with CHF.","PeriodicalId":311634,"journal":{"name":"2019 IEEE 32nd International Symposium on Computer-Based Medical Systems (CBMS)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE 32nd International Symposium on Computer-Based Medical Systems (CBMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMS.2019.00063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Portable ultrasound is increasingly used to assess jugular venous pressure (JVP) to approximate volume status in patients with congestive heart failure (CHF). Traditionally, increases in jugular venous pressure height signify increasing circulating blood volume. Emerging evidence, suggests that JVP correlates well with sonographic images of the internal jugular vein (IJV). This paper represents a preliminary investigation on the ability of cross-sectional area (CSA) of the IJV to measure relative changes in circulating blood volume. Fourteen healthy subjects had serial transverse ultrasound videos of their IJV captured while lying at five angles designed to simulate relative changes in blood volume. Ultrasound videos of the IJV were both manually and semi-automatically segmented, the CSA was measured, outliers were detected and removed, and Rotation Forest classifier was used to classify the data. By limiting the number of classes from five to three and removing outliers the accuracies improved from 59.50% to 91.05% and 62.74% to 91.89% for manual and semi-automatic segmentation, respectively. This pilot demonstrated that serial measurement of the CSA of the IJV in combination with machine learning techniques represents a viable opportunity to monitor changes in circulating blood volume in healthy subjects, setting the stage for a trial monitoring of patients with CHF.
利用超声和模拟技术检测循环血容量的相对变化
便携式超声越来越多地用于评估颈静脉压(JVP),以估计充血性心力衰竭(CHF)患者的容量状态。传统上,颈静脉压升高表示循环血容量增加。新出现的证据表明,JVP与颈内静脉(IJV)的超声图像密切相关。本文对IJV横截面积(CSA)测量循环血容量相对变化的能力进行了初步研究。14名健康受试者在以5个角度躺着时,用连续的横向超声录像拍摄他们的内室,以模拟血容量的相对变化。对IJV的超声视频进行人工和半自动分割,测量CSA,检测并去除异常值,使用Rotation Forest分类器对数据进行分类。通过将分类数量从5个限制到3个并去除异常值,人工分割和半自动分割的准确率分别从59.50%提高到91.05%和62.74%提高到91.89%。该试验表明,结合机器学习技术对IJV的CSA进行连续测量是监测健康受试者循环血容量变化的可行机会,为监测CHF患者的试验奠定了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信