{"title":"A current reconstruction algorithm for three-phase inverters using integrated current sensors in the low-side switches","authors":"S. Chakrabarti, T. Jahns, R. Lorenz","doi":"10.1109/IAS.2003.1257646","DOIUrl":null,"url":null,"abstract":"Power semiconductor switches that include integrated pilot current sensors create opportunities to eliminate external current sensors in three-phase inverter applications. Each of the three conventional low-side power switches in a three-phase inverter can be replaced by one of these special devices that is designed to provide a sensing level current that accurately mirrors its total forward current. Recognizing that the output current in each phase flows through the low-side switch for only a portion of the fundamental cycle, a technique has been developed to reconstruct the full phase current waveforms for R-L loads using only the incomplete phase current measurements. The performance characteristics of the proposed current reconstruction technique are experimentally verified, including demonstration of a closed-loop three-phase current regulator using the reconstructed current feedback from the integrated pilot current sensors.","PeriodicalId":288109,"journal":{"name":"38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003.","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"33","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2003.1257646","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 33
Abstract
Power semiconductor switches that include integrated pilot current sensors create opportunities to eliminate external current sensors in three-phase inverter applications. Each of the three conventional low-side power switches in a three-phase inverter can be replaced by one of these special devices that is designed to provide a sensing level current that accurately mirrors its total forward current. Recognizing that the output current in each phase flows through the low-side switch for only a portion of the fundamental cycle, a technique has been developed to reconstruct the full phase current waveforms for R-L loads using only the incomplete phase current measurements. The performance characteristics of the proposed current reconstruction technique are experimentally verified, including demonstration of a closed-loop three-phase current regulator using the reconstructed current feedback from the integrated pilot current sensors.