Effect of Measurement Probe Configuration in Undermoded Nested Cavity Tests

J. West, M. Bahadorzadeh, C. Bunting
{"title":"Effect of Measurement Probe Configuration in Undermoded Nested Cavity Tests","authors":"J. West, M. Bahadorzadeh, C. Bunting","doi":"10.1109/EMCSI38923.2020.9191537","DOIUrl":null,"url":null,"abstract":"A study of the effect of the field-sampling probe configuration used in nested-cavity measurements has been performed. The outer cavity was an overmoded reverberation chamber and the inner cavity was a small conducting enclosure that included a coupling aperture. Mechanical stirring within both the external and internal cavities was combined with frequency stirring to yield the mean received signal. Monopole, meanderline, and log-periodic probes were evaluated. The three-dimensional meanderline probes overall showed the best performance, better sampling the low-frequency signals where the inner cavity is undermoded. Despite the advantages, the mean signals levels still show a dependence on the specific configuration of the meanderline used, particularly at low frequency, and care must be used in interpreting the measured levels.","PeriodicalId":189322,"journal":{"name":"2020 IEEE International Symposium on Electromagnetic Compatibility & Signal/Power Integrity (EMCSI)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Symposium on Electromagnetic Compatibility & Signal/Power Integrity (EMCSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCSI38923.2020.9191537","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A study of the effect of the field-sampling probe configuration used in nested-cavity measurements has been performed. The outer cavity was an overmoded reverberation chamber and the inner cavity was a small conducting enclosure that included a coupling aperture. Mechanical stirring within both the external and internal cavities was combined with frequency stirring to yield the mean received signal. Monopole, meanderline, and log-periodic probes were evaluated. The three-dimensional meanderline probes overall showed the best performance, better sampling the low-frequency signals where the inner cavity is undermoded. Despite the advantages, the mean signals levels still show a dependence on the specific configuration of the meanderline used, particularly at low frequency, and care must be used in interpreting the measured levels.
欠模套腔试验中测量探头配置的影响
研究了在巢腔测量中使用的现场采样探针结构的影响。外腔是一个过时的混响室,内腔是一个小的导电外壳,包括一个耦合孔。外腔和内腔的机械搅拌与频率搅拌相结合,得到平均接收信号。单极,曲线和对数周期探针进行了评估。三维弯曲线探头总体上表现出最好的性能,能够更好地采样内腔欠模处的低频信号。尽管有这些优点,但平均信号电平仍然显示出对所使用的曲线的特定配置的依赖,特别是在低频时,在解释测量的电平时必须小心。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信