Differential Protection of Microgrid based on Rate of Change of Apparent Power

Abinash Nanda, Nityananda Giri, P. Nayak, R. Mallick, Sairam Mishra, A. Choudhury
{"title":"Differential Protection of Microgrid based on Rate of Change of Apparent Power","authors":"Abinash Nanda, Nityananda Giri, P. Nayak, R. Mallick, Sairam Mishra, A. Choudhury","doi":"10.1109/GlobConPT57482.2022.9938363","DOIUrl":null,"url":null,"abstract":"Increasing penetration of renewable energy sources in microgrid increases the complexity of coordinated control and protection issues. Differential protection seems to be reliable and accurate. This research proposed a new differential protection scheme to detect different types of series and shunt faults using rate of change of apparent power. This proposed technique has been implemented using MATLAB with a standard microgrid test system. Simulation results show that the proposed method is able to detect faults with less detection time and higher accuracy.","PeriodicalId":431406,"journal":{"name":"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Global Conference on Computing, Power and Communication Technologies (GlobConPT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GlobConPT57482.2022.9938363","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Increasing penetration of renewable energy sources in microgrid increases the complexity of coordinated control and protection issues. Differential protection seems to be reliable and accurate. This research proposed a new differential protection scheme to detect different types of series and shunt faults using rate of change of apparent power. This proposed technique has been implemented using MATLAB with a standard microgrid test system. Simulation results show that the proposed method is able to detect faults with less detection time and higher accuracy.
基于视在功率变化率的微电网差动保护
微电网中可再生能源的日益普及增加了协调控制和保护问题的复杂性。差动保护似乎是可靠和准确的。提出了一种利用视在功率变化率检测不同类型串联和并联故障的差动保护方案。该技术已在一个标准的微电网测试系统上用MATLAB实现。仿真结果表明,该方法能够以较短的检测时间和较高的检测精度检测故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信