Design of an Electromyograph Equipped with Digital Neck Angle Elevation Gauge

Ahmad Kamil Solihin, Endro Yulianto, Her Gumiwang Ariswati, K. K. M. Rahman
{"title":"Design of an Electromyograph Equipped with Digital Neck Angle Elevation Gauge","authors":"Ahmad Kamil Solihin, Endro Yulianto, Her Gumiwang Ariswati, K. K. M. Rahman","doi":"10.35882/jeeemi.v3i3.4","DOIUrl":null,"url":null,"abstract":"The development of technology also affects human health, including body posture due to poor human position when using gadgets, both smartphones, and laptops. This study is design a tool that can measure the elevation of a person's neck angle equipped with electromyography, to help health workers, medical rehabilitation doctors to diagnose and provide treatment to patients with a bent head posture or forward head posture. In this research, an electromyography module is designed which consists of a series of instruments, a pre-amplifier circuit, a high pass filter, a low pass filter, and a dc offset regulator to be converted to digital so that it can be displayed on a laptop. In this study, the tapped muscle was the upper trapezius muscle using disposable electrodes. Meanwhile, to measure the angular elevation, the MPU 6050 sensor is used to measure the movement of the head forward. The frequency of the electromyography signal is 20-500 Hz. For software or display readings from this tool is Delphy. Meanwhile, the microcontroller used for ADC communication is Arduino Uno. From the research, it was found that the neck angle elevation gauge has a 0,597% error rate, for conditioning conducted on respondents, all respondents experienced a decrease in amplitude on the same frequency spectrum in the last ten minutes. Meanwhile, a drastic decrease occurred at the neck angle of 60°. Thus, it can be concluded that the forward position of the head affects the frequency spectrum of the neck muscles.","PeriodicalId":369032,"journal":{"name":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","volume":"109 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35882/jeeemi.v3i3.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The development of technology also affects human health, including body posture due to poor human position when using gadgets, both smartphones, and laptops. This study is design a tool that can measure the elevation of a person's neck angle equipped with electromyography, to help health workers, medical rehabilitation doctors to diagnose and provide treatment to patients with a bent head posture or forward head posture. In this research, an electromyography module is designed which consists of a series of instruments, a pre-amplifier circuit, a high pass filter, a low pass filter, and a dc offset regulator to be converted to digital so that it can be displayed on a laptop. In this study, the tapped muscle was the upper trapezius muscle using disposable electrodes. Meanwhile, to measure the angular elevation, the MPU 6050 sensor is used to measure the movement of the head forward. The frequency of the electromyography signal is 20-500 Hz. For software or display readings from this tool is Delphy. Meanwhile, the microcontroller used for ADC communication is Arduino Uno. From the research, it was found that the neck angle elevation gauge has a 0,597% error rate, for conditioning conducted on respondents, all respondents experienced a decrease in amplitude on the same frequency spectrum in the last ten minutes. Meanwhile, a drastic decrease occurred at the neck angle of 60°. Thus, it can be concluded that the forward position of the head affects the frequency spectrum of the neck muscles.
配备数字式颈角仰角计的肌电仪设计
科技的发展也影响着人类的健康,包括由于使用智能手机和笔记本电脑等电子产品时人体姿势不当而导致的身体姿势。本研究设计了一种配备肌电图的工具,可以测量人颈部角度的升高,以帮助卫生工作者、医疗康复医生对头屈或头前的患者进行诊断和治疗。在本研究中,设计了一个肌电图模块,该模块由一系列仪器、前置放大电路、高通滤波器、低通滤波器和直流偏置稳压器组成,并将其转换为数字,以便在笔记本电脑上显示。在本研究中,使用一次性电极轻叩的肌肉为斜方肌上部。同时,为了测量角度仰角,使用MPU 6050传感器测量头部向前的运动。肌电信号的频率为20- 500hz。软件或显示读数从这个工具是德尔福。同时,用于ADC通信的微控制器是Arduino Uno。从研究中发现,颈部角仰角计的错误率为0.597 %,对于被调查者进行调节,所有被调查者在最近十分钟内都经历了同一频谱上幅度的下降。同时,颈角为60°时出现了剧烈的下降。因此,可以得出结论,头部的前倾位置影响颈部肌肉的频谱。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信