Assessment of Distribution System Feeder and its Reconfiguration using fuzzy adaptive evolutionary computing

S. Karthikeyan, V. Verma, D. Agrawal, R. Jacob, D. Kothari
{"title":"Assessment of Distribution System Feeder and its Reconfiguration using fuzzy adaptive evolutionary computing","authors":"S. Karthikeyan, V. Verma, D. Agrawal, R. Jacob, D. Kothari","doi":"10.1109/INDCON.2008.4768833","DOIUrl":null,"url":null,"abstract":"Distribution system automation (DSA) is being carried out very seriously world over to enhance the reliability of the system and to minimize the huge losses that are occurring in the distribution system. With the fast-paced changing technologies in the distribution sector, the automation of distribution system is unavoidable. Feeder reconfiguration (FR) is one of the vital operations to be carried out in successful implementation of the DSA. FR can be varied so that the load is supplied at the cost of possible minimal line losses, increased system security and enhanced power quality. Several attempts have been made in the past to obtain an optimal feeder configuration for minimizing losses in distribution systems. Feeder reconfiguration (FR) is an important sub-problem of the overall distribution system automation process. To get the optimized system configuration, first step is to detect whether the system is abnormal enough to have any other configuration from present case. To serve this purpose, S-difference criterion is proposed to detect whether the system is making transition from normal to abnormal state of operation. After detecting the abnormality, the situation arises to find whether the line through which the power is going to be rerouted can sustain the increment. This is identified by calculating the availability transfer capability (ATC) of the lines in the system. Linear and modified ATC has been proposed in this paper to serve the required purpose. After assessing the state of the system, its reconfiguration is done by fuzzy adaptation of evolutionary computing, to get the optimized system performance. Fuzzy adaptation has been introduced to take into account the grey area between various parameters considered and the obtained result is supposed to satisfy all the constraints to the optimum degree of fuzzy membership function. Vellore 75 bus real distribution system has been used as a test system for simulation purposes.","PeriodicalId":196254,"journal":{"name":"2008 Annual IEEE India Conference","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual IEEE India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INDCON.2008.4768833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Distribution system automation (DSA) is being carried out very seriously world over to enhance the reliability of the system and to minimize the huge losses that are occurring in the distribution system. With the fast-paced changing technologies in the distribution sector, the automation of distribution system is unavoidable. Feeder reconfiguration (FR) is one of the vital operations to be carried out in successful implementation of the DSA. FR can be varied so that the load is supplied at the cost of possible minimal line losses, increased system security and enhanced power quality. Several attempts have been made in the past to obtain an optimal feeder configuration for minimizing losses in distribution systems. Feeder reconfiguration (FR) is an important sub-problem of the overall distribution system automation process. To get the optimized system configuration, first step is to detect whether the system is abnormal enough to have any other configuration from present case. To serve this purpose, S-difference criterion is proposed to detect whether the system is making transition from normal to abnormal state of operation. After detecting the abnormality, the situation arises to find whether the line through which the power is going to be rerouted can sustain the increment. This is identified by calculating the availability transfer capability (ATC) of the lines in the system. Linear and modified ATC has been proposed in this paper to serve the required purpose. After assessing the state of the system, its reconfiguration is done by fuzzy adaptation of evolutionary computing, to get the optimized system performance. Fuzzy adaptation has been introduced to take into account the grey area between various parameters considered and the obtained result is supposed to satisfy all the constraints to the optimum degree of fuzzy membership function. Vellore 75 bus real distribution system has been used as a test system for simulation purposes.
基于模糊自适应进化计算的配电系统馈线评价及其重构
为了提高配电系统的可靠性,尽量减少配电系统中出现的巨大损失,配电系统自动化(DSA)在世界范围内得到了广泛的应用。随着配电行业技术的快速发展,配电系统的自动化势在必行。馈线重新配置(FR)是成功实施DSA的关键操作之一。FR可以改变,以便以可能的最小线路损耗为代价提供负载,增加系统安全性并增强电能质量。为了使配电系统的损耗最小化,过去已经进行了多次尝试,以获得最佳馈线配置。馈线重构是整个配电系统自动化过程中的一个重要子问题。为了获得优化的系统配置,第一步是检测系统是否异常到足以从当前情况中获得任何其他配置。为此,提出s差分准则来检测系统是否处于由正常运行状态向异常运行状态过渡的状态。在检测到异常后,出现的情况是,查看将要重路由的线路是否可以承受增量。这可以通过计算系统中线路的可用性传输能力(ATC)来确定。本文提出了线性和改进的ATC,以满足所需的目的。在对系统状态进行评估后,利用进化计算的模糊自适应对系统进行重构,以获得最优的系统性能。引入了模糊自适应,考虑了所考虑参数之间的灰色区域,得到的结果应满足模糊隶属函数最优度的所有约束。采用velloel75总线真实配电系统作为仿真测试系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信