Factors and uncertainty evaluation of quasi-static method for measuring piezoelectric constant

Longbiao He, Hong Wu, Jing-lin Zhou, Haijiang Zhu, Ping Yang
{"title":"Factors and uncertainty evaluation of quasi-static method for measuring piezoelectric constant","authors":"Longbiao He, Hong Wu, Jing-lin Zhou, Haijiang Zhu, Ping Yang","doi":"10.1109/SPAWDA.2014.6998575","DOIUrl":null,"url":null,"abstract":"Quasi-static method is recommended by international standards to measure the piezoelectric constant d33 of piezoelectric ceramics. To calibrate the quasi-staticapparatus, a system directly based on quasi-static force and electric charge measurement was developed. The factors were studied and the uncertainty was evaluated. The test results showed that the static force had different effect on hard and soft ceramics materials, and the frequency and the amplitude of driving force made significant impact. The uncertainty evaluation indicated that the d33 measurement of quasi-static method is no more than 4 % (k=2) for PZT4 and PZT5 materials.","PeriodicalId":412736,"journal":{"name":"Proceedings of the 2014 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2014 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPAWDA.2014.6998575","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Quasi-static method is recommended by international standards to measure the piezoelectric constant d33 of piezoelectric ceramics. To calibrate the quasi-staticapparatus, a system directly based on quasi-static force and electric charge measurement was developed. The factors were studied and the uncertainty was evaluated. The test results showed that the static force had different effect on hard and soft ceramics materials, and the frequency and the amplitude of driving force made significant impact. The uncertainty evaluation indicated that the d33 measurement of quasi-static method is no more than 4 % (k=2) for PZT4 and PZT5 materials.
准静态法测量压电常数的影响因素及不确定度评定
准静态法是国际标准推荐的测量压电陶瓷压电常数d33的方法。为了校准准静力仪,研制了一种直接基于准静力和电荷测量的准静力仪校准系统。对影响因素进行了研究,并对不确定度进行了评定。试验结果表明,静力对硬、软陶瓷材料的影响不同,驱动力的频率和幅值有显著影响。不确定度评定表明,准静态法对PZT4和PZT5材料的d33测量值不大于4% (k=2)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信