{"title":"Plane displacement measurement of rigid body by laser speckle","authors":"Chuan Zhong, Changyu Shen, L. Xiang, Ke Li","doi":"10.1117/12.887706","DOIUrl":null,"url":null,"abstract":"A measurement system of plane displacement in rigid body was designed. Plane displacement was calculated by the cross-correlation of speckle image. Measurement results showed that the absolute-error and the opposite-error of the plane displacement less than ±14µm and ±6.25% respectively, under the displacement range of 300 µm.","PeriodicalId":126232,"journal":{"name":"Asia Communications and Photonics Conference and Exhibition","volume":"75 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia Communications and Photonics Conference and Exhibition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.887706","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A measurement system of plane displacement in rigid body was designed. Plane displacement was calculated by the cross-correlation of speckle image. Measurement results showed that the absolute-error and the opposite-error of the plane displacement less than ±14µm and ±6.25% respectively, under the displacement range of 300 µm.