{"title":"EMC of PV-plants with line-commutated inverters","authors":"A. Kempe, Uwe Schonwandt","doi":"10.1109/PVSC.1996.564382","DOIUrl":null,"url":null,"abstract":"The new European EMC (electromagnetic compatibility) standard (EN 61000-3-2) became valid from the beginning of 1996, and although a revision may already be considered, producers of PV-inverters will have to face a growing interest in their equipment's EMC-properties. In the case of line-commutated inverters EMC-problems are mainly related with current harmonics and power factor. In this paper it is shown by simulation and measurements that a usual 6-pulse inverter will cope with the above standards in the whole range of operation up to 11 kW, if an adequate passive LC-filter is introduced into the grid connection. Since this filter almost does not affect the inverter's efficiency, it is considered to be a very effective and economic solution to line bound EMC-problems. The results are presented in the form of diagrams for easy reference to the designer. The radio interference can be avoided using the standard thyristor RC-damping against fast voltage gradients.","PeriodicalId":410394,"journal":{"name":"Conference Record of the Twenty Fifth IEEE Photovoltaic Specialists Conference - 1996","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the Twenty Fifth IEEE Photovoltaic Specialists Conference - 1996","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PVSC.1996.564382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
Abstract
The new European EMC (electromagnetic compatibility) standard (EN 61000-3-2) became valid from the beginning of 1996, and although a revision may already be considered, producers of PV-inverters will have to face a growing interest in their equipment's EMC-properties. In the case of line-commutated inverters EMC-problems are mainly related with current harmonics and power factor. In this paper it is shown by simulation and measurements that a usual 6-pulse inverter will cope with the above standards in the whole range of operation up to 11 kW, if an adequate passive LC-filter is introduced into the grid connection. Since this filter almost does not affect the inverter's efficiency, it is considered to be a very effective and economic solution to line bound EMC-problems. The results are presented in the form of diagrams for easy reference to the designer. The radio interference can be avoided using the standard thyristor RC-damping against fast voltage gradients.