{"title":"On-line Junction Temperature Measurement of CoolMOS Devices","authors":"Andreas Koenig, T. Plum, Peter Fidler, R. D. Doncker","doi":"10.1109/PEDS.2007.4487683","DOIUrl":null,"url":null,"abstract":"To operate power electronic devices at high ambient temperatures it has to be ensured that the maximum specified junction temperature is not exceeded at any time during operation. This paper presents a method to calculate the actual junction temperature by measuring voltage and current at a power MOSFET during operation of a converter. Based on this temperature, the actual transferred power of a converter can be controlled to ensure a safe operation within the specified temperature limits.","PeriodicalId":166704,"journal":{"name":"2007 7th International Conference on Power Electronics and Drive Systems","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"54","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 7th International Conference on Power Electronics and Drive Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2007.4487683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 54

Abstract

To operate power electronic devices at high ambient temperatures it has to be ensured that the maximum specified junction temperature is not exceeded at any time during operation. This paper presents a method to calculate the actual junction temperature by measuring voltage and current at a power MOSFET during operation of a converter. Based on this temperature, the actual transferred power of a converter can be controlled to ensure a safe operation within the specified temperature limits.
CoolMOS器件结温在线测量
为了在高温环境下运行电力电子设备,必须确保在运行过程中任何时候都不超过规定的最高结温。本文提出了一种通过测量功率MOSFET在变换器工作时的电压和电流来计算实际结温的方法。根据该温度,可以控制转换器的实际传输功率,以确保在规定的温度范围内安全运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信