Allocation Of Res And Dstatcom For The Optimal Distribution System Planning

Madhur Shukla, P. Jain
{"title":"Allocation Of Res And Dstatcom For The Optimal Distribution System Planning","authors":"Madhur Shukla, P. Jain","doi":"10.1109/NPSC57038.2022.10069275","DOIUrl":null,"url":null,"abstract":"The increasing demand of the load causes the voltage imbalance and increase in power loss. This is forcing the distribution companies to take the proper actions in the planning of distribution system. The allocation of Renewable Energy Source (RES) and Distribution Static Compensator (DSTATCOM) are considered in the distribution system planning to reduce the losses and maintain the voltage of the system within the required limit with the growing load demand. Due to the environmental concerns, the RES is becoming the must to consider as a part of the power system whereas the use of DSTATCOM is for the reactive power compensation to improve the power quality and the voltage profile. For the simultaneous allocation of RES and DSTATCOM in balanced Radial Distribution System (RDS), Loss Sensitivity Factor (LSF) used to get the candidate buses and Particle Swarm optimization (PSO) algorithm is used for optimal sizes. For the calculation of load flow of the system an efficient Backward-Forward Sweep Load Flow Algorithm is used. The objective of the proposed methodology is to minimize the total cost which is the sum of total investment cost of RES and DSTATCOM, power purchase cost and pollution emission cost, keeping the voltage of each bus of the system within the limit. From the result obtained for the 38-bus balanced radial distribution system (RDS), it is clearly observed that the total active and reactive power losses are reduced and voltages of the system is improved with the optimal allocation of RES and DSTATCOM at minimum cost.","PeriodicalId":162808,"journal":{"name":"2022 22nd National Power Systems Conference (NPSC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 22nd National Power Systems Conference (NPSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NPSC57038.2022.10069275","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The increasing demand of the load causes the voltage imbalance and increase in power loss. This is forcing the distribution companies to take the proper actions in the planning of distribution system. The allocation of Renewable Energy Source (RES) and Distribution Static Compensator (DSTATCOM) are considered in the distribution system planning to reduce the losses and maintain the voltage of the system within the required limit with the growing load demand. Due to the environmental concerns, the RES is becoming the must to consider as a part of the power system whereas the use of DSTATCOM is for the reactive power compensation to improve the power quality and the voltage profile. For the simultaneous allocation of RES and DSTATCOM in balanced Radial Distribution System (RDS), Loss Sensitivity Factor (LSF) used to get the candidate buses and Particle Swarm optimization (PSO) algorithm is used for optimal sizes. For the calculation of load flow of the system an efficient Backward-Forward Sweep Load Flow Algorithm is used. The objective of the proposed methodology is to minimize the total cost which is the sum of total investment cost of RES and DSTATCOM, power purchase cost and pollution emission cost, keeping the voltage of each bus of the system within the limit. From the result obtained for the 38-bus balanced radial distribution system (RDS), it is clearly observed that the total active and reactive power losses are reduced and voltages of the system is improved with the optimal allocation of RES and DSTATCOM at minimum cost.
配电系统最优规划中的资源分配与Dstatcom
负载需求的增加导致电压不平衡,功率损耗增大。这就迫使配电公司在配电系统的规划中采取适当的行动。随着负荷需求的增长,配电系统规划中考虑了可再生能源(RES)和配电静态补偿器(DSTATCOM)的配置,以降低系统损耗并使系统电压保持在要求的范围内。由于环境问题,可再生能源正成为电力系统必须考虑的一部分,而DSTATCOM的使用是为了无功补偿,以改善电能质量和电压分布。针对平衡型径向配电系统中RES和DSTATCOM的同时分配问题,采用损耗敏感因子(LSF)确定候选总线,并采用粒子群优化(PSO)算法进行优化。对于系统的潮流计算,采用了一种高效的后向扫描潮流算法。所提出的方法的目标是使总成本最小,即RES和DSTATCOM的总投资成本、购电成本和污染排放成本的总和,使系统各母线的电压保持在限制范围内。对38母线均衡径向配电系统(RDS)的仿真结果表明,以最小的成本优化配置RES和DSTATCOM,可以降低系统的总有功和无功损耗,提高系统电压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信