A method of rapid detection of the grid voltage

S. Change, Xiangwu Yan, Qingli Zhang, Hongchang Liu, Huichao Zhao, Lin Li
{"title":"A method of rapid detection of the grid voltage","authors":"S. Change, Xiangwu Yan, Qingli Zhang, Hongchang Liu, Huichao Zhao, Lin Li","doi":"10.1109/ICSET.2012.6357436","DOIUrl":null,"url":null,"abstract":"That large-scale wind farm connects to the power grid has affected the safe and stable operation of the grid. Low Voltage ride through (LVRT) capability is required by new power system operating codes. At the same time, the sudden change of the grid voltage is a shock for wind turbine. Fast and accurate detection of grid voltage sudden change fault is an important condition to achieve safe operation of the power grid and LVRT of wind power system. This paper fully analyzes the existing voltage sudden change detection method and presents a method of comparing the instantaneous value of test signals with the instantaneous value of “standard sinusoidal digital signal”. It generates the standard signal with the same frequency and phase as the test signal by Phase Locked Loop (PLL) technology. It gets values of test signal at some point in a cycle by the digital signal processing technology. Then, the difference between each present value of test signal and its corresponding “standard sinusoidal digital signal” values is used to reflect the real-time status of the signal under test. This instantaneous value comparison method can accurately and without delay detect the sudden change of voltage (sudden drop or a sudden jump in) and the computing is small. In order to ensure the accuracy of the detection without changes in grid frequency, but also from the impact of voltage sag depth, we improve the PLL signal input circuit. The fast and accurate detection of the grid voltage sudden change supplies the timely and accurate condition for wind turbine to through the low voltage.","PeriodicalId":256740,"journal":{"name":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSET.2012.6357436","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

That large-scale wind farm connects to the power grid has affected the safe and stable operation of the grid. Low Voltage ride through (LVRT) capability is required by new power system operating codes. At the same time, the sudden change of the grid voltage is a shock for wind turbine. Fast and accurate detection of grid voltage sudden change fault is an important condition to achieve safe operation of the power grid and LVRT of wind power system. This paper fully analyzes the existing voltage sudden change detection method and presents a method of comparing the instantaneous value of test signals with the instantaneous value of “standard sinusoidal digital signal”. It generates the standard signal with the same frequency and phase as the test signal by Phase Locked Loop (PLL) technology. It gets values of test signal at some point in a cycle by the digital signal processing technology. Then, the difference between each present value of test signal and its corresponding “standard sinusoidal digital signal” values is used to reflect the real-time status of the signal under test. This instantaneous value comparison method can accurately and without delay detect the sudden change of voltage (sudden drop or a sudden jump in) and the computing is small. In order to ensure the accuracy of the detection without changes in grid frequency, but also from the impact of voltage sag depth, we improve the PLL signal input circuit. The fast and accurate detection of the grid voltage sudden change supplies the timely and accurate condition for wind turbine to through the low voltage.
一种快速检测电网电压的方法
大型风电场的并网问题影响着电网的安全稳定运行。新的电力系统运行规范对低电压穿越(LVRT)能力提出了要求。同时,电网电压的突然变化对风力发电机组是一种冲击。快速准确地检测电网电压突变故障是实现电网和风电系统LVRT安全运行的重要条件。本文充分分析了现有的电压突变检测方法,提出了一种将测试信号的瞬时值与“标准正弦数字信号”的瞬时值进行比较的方法。它通过锁相环(PLL)技术产生与测试信号具有相同频率和相位的标准信号。它通过数字信号处理技术获取一个周期内某点的测试信号值。然后,用每个测试信号的现值与其对应的“标准正弦数字信号”值的差值来反映被测信号的实时状态。这种瞬时值比较法可以准确、无延迟地检测电压的突然变化(突然下降或突然上升),计算量小。为了在不改变电网频率的情况下保证检测的准确性,同时也不受电压凹陷深度的影响,我们对锁相环信号输入电路进行了改进。对电网电压突变的快速、准确检测,为风电机组渡过低压提供了及时、准确的条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信