Reconstructing high-resolution cardiac MR movies from under-sampled frames

L. Cattell, C. Meyer, F. Epstein, G. Rohde
{"title":"Reconstructing high-resolution cardiac MR movies from under-sampled frames","authors":"L. Cattell, C. Meyer, F. Epstein, G. Rohde","doi":"10.1109/ACSSC.2017.8335553","DOIUrl":null,"url":null,"abstract":"In medicine, high-resolution magnetic resonance imaging can aid accurate diagnosis. However, high-resolution magnetic resonance imaging usually necessitates a longer acquisition time than low-resolution imaging, since the resolution of magnetic resonance images is determined by the extent of k-space that is sampled. Long scan times can induce motion artifacts in the images and lead to patient discomfort, and therefore, scan times should be kept as low as possible. Although a short acquisition time comes at the expense of spatial resolution, the resolution of magnetic resonance images can be increased using post-processing methods. In this work, we present one such method designed for cardiac magnetic resonance movies. Our method uses deformable image registration to capture the motion of the heart, and an additional term to account for changes in pixel intensity. We demonstrate that our method has the potential to reconstruct high-resolution cardiac magnetic resonance movies from highly under-sampled data, using only a single high-resolution reference frame.","PeriodicalId":296208,"journal":{"name":"2017 51st Asilomar Conference on Signals, Systems, and Computers","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 51st Asilomar Conference on Signals, Systems, and Computers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACSSC.2017.8335553","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In medicine, high-resolution magnetic resonance imaging can aid accurate diagnosis. However, high-resolution magnetic resonance imaging usually necessitates a longer acquisition time than low-resolution imaging, since the resolution of magnetic resonance images is determined by the extent of k-space that is sampled. Long scan times can induce motion artifacts in the images and lead to patient discomfort, and therefore, scan times should be kept as low as possible. Although a short acquisition time comes at the expense of spatial resolution, the resolution of magnetic resonance images can be increased using post-processing methods. In this work, we present one such method designed for cardiac magnetic resonance movies. Our method uses deformable image registration to capture the motion of the heart, and an additional term to account for changes in pixel intensity. We demonstrate that our method has the potential to reconstruct high-resolution cardiac magnetic resonance movies from highly under-sampled data, using only a single high-resolution reference frame.
从欠采样帧重建高分辨率心脏MR电影
在医学上,高分辨率磁共振成像可以帮助准确诊断。然而,高分辨率磁共振成像通常需要比低分辨率成像更长的采集时间,因为磁共振图像的分辨率取决于采样的k空间的程度。长时间扫描会引起图像中的运动伪影,导致患者不适,因此,扫描时间应尽可能低。虽然较短的采集时间是以牺牲空间分辨率为代价的,但使用后处理方法可以提高磁共振图像的分辨率。在这项工作中,我们提出了一种设计用于心脏磁共振电影的方法。我们的方法使用可变形图像配准来捕捉心脏的运动,并使用额外的术语来解释像素强度的变化。我们证明,我们的方法有潜力从高度欠采样的数据中重建高分辨率心脏磁共振电影,仅使用单个高分辨率参考帧。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信