{"title":"Efficiency, Economic and Environmental Assessment of Ground Source Heat Pumps in Central Pennsylvania","authors":"S. Blumsack, J. Brownson, Lucas Witmer","doi":"10.1109/HICSS.2009.179","DOIUrl":null,"url":null,"abstract":"The energy use of a ground-source heat pump (GSP) for heating, cooling and hot water in a Central Pennsylvania residence (namely, the author's house) is analyzed, compared to a simulation of electricity and a heating-oil furnace (with electric cooling) for these same energy uses. Energy demands for space conditioning in the house are simulated by building a model of the house using the Transient Energy System Simulation (TNRSYS) tool. Overall, the efficiency gain for the ground-source heat pump compared to electricity is 43% for cooling and 81% for heating. For home heating and hot water, the ground-source heat pump has a 42% efficiency gain over a fuel-oil furnace. The system modeled in this paper has a payback period of between four and five years compared to an all-electric system. The payback period compared to a hybrid system of fuel-oil heat and electric cooling is between two and three years.","PeriodicalId":211759,"journal":{"name":"2009 42nd Hawaii International Conference on System Sciences","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 42nd Hawaii International Conference on System Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HICSS.2009.179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23
Abstract
The energy use of a ground-source heat pump (GSP) for heating, cooling and hot water in a Central Pennsylvania residence (namely, the author's house) is analyzed, compared to a simulation of electricity and a heating-oil furnace (with electric cooling) for these same energy uses. Energy demands for space conditioning in the house are simulated by building a model of the house using the Transient Energy System Simulation (TNRSYS) tool. Overall, the efficiency gain for the ground-source heat pump compared to electricity is 43% for cooling and 81% for heating. For home heating and hot water, the ground-source heat pump has a 42% efficiency gain over a fuel-oil furnace. The system modeled in this paper has a payback period of between four and five years compared to an all-electric system. The payback period compared to a hybrid system of fuel-oil heat and electric cooling is between two and three years.