Performance Analysis And Mitigation Of Power Quality Issues With Hybrid B – Statcom In 140 Bus Distribution System Connected To Scig Wind Turbine

K. V. Ramana Reddy, K. Ravi
{"title":"Performance Analysis And Mitigation Of Power Quality Issues With Hybrid B – Statcom In 140 Bus Distribution System Connected To Scig Wind Turbine","authors":"K. V. Ramana Reddy, K. Ravi","doi":"10.1109/ICCPEIC45300.2019.9082396","DOIUrl":null,"url":null,"abstract":"This paper gives the Performance Analysis and Mitigation of Power Quality Issues with Hybrid B–STATCOM in 140 Bus Distribution System Connected To SCIG Wind Turbine. It is an important task to maintain the power quality within the system operating limits and facilities in a distributed power grid. In the developed 140 bus system a hybrid battery energy storage system and STATCOM (BSTATCOM) with hysteresis current control strategy is proposed for an inverter to improve power quality with an exchange of current and voltage simultaneously. The operation mode switches a flawless transfer of the operation mode from grid-connected to stand-alone or vice versa. The outside of an islanded bus voltage loop and inside B – STATCOM inverter current loop, controllers are designed using h current control strategy with three phase and four wire system. The injected currents are clean, balanced and free from harmonics. The islanded bus relives from the main power supply and the demand of reactive power supplied from the squirrel cage induction generator and B – STATCOM follows the rules of grid operation as per IEC 61400 – 21. The control scheme of 140 bus distribution power grid connected SCIG wind energy system verified using simulation MATLAB/ SIMULINK power system block sets.","PeriodicalId":120930,"journal":{"name":"2019 International Conference on Computation of Power, Energy, Information and Communication (ICCPEIC)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Computation of Power, Energy, Information and Communication (ICCPEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCPEIC45300.2019.9082396","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper gives the Performance Analysis and Mitigation of Power Quality Issues with Hybrid B–STATCOM in 140 Bus Distribution System Connected To SCIG Wind Turbine. It is an important task to maintain the power quality within the system operating limits and facilities in a distributed power grid. In the developed 140 bus system a hybrid battery energy storage system and STATCOM (BSTATCOM) with hysteresis current control strategy is proposed for an inverter to improve power quality with an exchange of current and voltage simultaneously. The operation mode switches a flawless transfer of the operation mode from grid-connected to stand-alone or vice versa. The outside of an islanded bus voltage loop and inside B – STATCOM inverter current loop, controllers are designed using h current control strategy with three phase and four wire system. The injected currents are clean, balanced and free from harmonics. The islanded bus relives from the main power supply and the demand of reactive power supplied from the squirrel cage induction generator and B – STATCOM follows the rules of grid operation as per IEC 61400 – 21. The control scheme of 140 bus distribution power grid connected SCIG wind energy system verified using simulation MATLAB/ SIMULINK power system block sets.
与Scig风力发电机连接的140母线配电网混合B - Statcom的性能分析及电能质量问题缓解
本文给出了与SCIG风力发电机组连接的140母线配电网混合B-STATCOM的性能分析及电能质量问题的解决方法。在分布式电网中,保证电能质量在系统运行限值和设施范围内是一项重要的任务。在已开发的140母线系统中,提出了一种具有滞后电流控制策略的混合电池储能系统和STATCOM (BSTATCOM)逆变器,通过同时交换电流和电压来改善电能质量。该操作模式将操作模式从并网转换为独立模式,反之亦然。控制器外设孤岛母线电压环,内设B - STATCOM逆变电流环,采用三相四线制电流控制策略。注入的电流干净、平衡、无谐波。孤岛母线从主电源和鼠笼式感应发电机和B - STATCOM提供的无功功率需求中解脱出来,遵循IEC 61400 - 21的电网运行规则。利用MATLAB/ SIMULINK仿真电力系统块集,验证了140母线配电网连接SCIG风能系统的控制方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信