{"title":"Adaptive signal processing system for accurate zero-crossing detection of cycloconverter phase currents","authors":"S. Valiviita, S. Ovaska, J. Kyyra","doi":"10.1109/PCCON.1997.645656","DOIUrl":null,"url":null,"abstract":"The authors introduce a multistage adaptive digital filtering system for the processing of cycloconverter phase current signals. In cycloconverter drives, the zero current periods, related to the changing of thyristor bridges, cause torque distortion, which impairs the performance of speed control. The proposed filtering system is used for accurate zero-crossing detection in order to shorten the mandatory zero current periods. The authors' filtering system combines a low-pass prefilter and an adaptive predictive filter making it possible to extract the sinusoidal primary signal from noise and disturbances without harmfully phase shifting the fundamental component even when the frequency or amplitude alters rapidly. The predictive filtering is performed at time-varying sampling rate, so that the relative frequency of the fundamental component remains almost constant.","PeriodicalId":262154,"journal":{"name":"Proceedings of Power Conversion Conference - PCC '97","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Power Conversion Conference - PCC '97","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCCON.1997.645656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

The authors introduce a multistage adaptive digital filtering system for the processing of cycloconverter phase current signals. In cycloconverter drives, the zero current periods, related to the changing of thyristor bridges, cause torque distortion, which impairs the performance of speed control. The proposed filtering system is used for accurate zero-crossing detection in order to shorten the mandatory zero current periods. The authors' filtering system combines a low-pass prefilter and an adaptive predictive filter making it possible to extract the sinusoidal primary signal from noise and disturbances without harmfully phase shifting the fundamental component even when the frequency or amplitude alters rapidly. The predictive filtering is performed at time-varying sampling rate, so that the relative frequency of the fundamental component remains almost constant.
自适应信号处理系统用于环变换器相位电流的精确过零检测
介绍了一种用于处理环变换器相电流信号的多级自适应数字滤波系统。在环变换器驱动中,与晶闸管桥的变化有关的零电流周期会引起转矩畸变,从而影响速度控制的性能。该滤波系统用于精确的过零检测,以缩短强制零电流周期。作者的滤波系统结合了低通预滤波器和自适应预测滤波器,使其能够从噪声和干扰中提取正弦初级信号,即使在频率或幅度迅速变化时也不会对基本分量产生有害的相移。预测滤波是在时变采样率下进行的,因此基本分量的相对频率几乎保持不变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信