{"title":"Mikronika's new solutions for power substations with the process bus technology","authors":"M. Ptaszyński, Przemysław Wronek","doi":"10.1109/ICSES.2014.6948731","DOIUrl":null,"url":null,"abstract":"This document presents a description of modern solutions dedicated to power substations which apply technologies compliant with the IEC 61850-9-2 standard. It provides information about, among others, a new group of devices which are currently developed by Mikronika which functionality will be extended with transmitting samples of analog and binary signals using efficient communication connections creating a so-called process bus. Moreover, it discusses the issue of precise time synchronization compliant with the IEC 61588 standard, ensuring correct operation of an entire system. An indispensable element of a modern substation automation system is redundancy on the communication level. This document presents solutions which, in contemporary reality, enable to meet requirements connected with lossless data transmission.","PeriodicalId":115109,"journal":{"name":"2014 International Conference on Signals and Electronic Systems (ICSES)","volume":"24 1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Signals and Electronic Systems (ICSES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSES.2014.6948731","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This document presents a description of modern solutions dedicated to power substations which apply technologies compliant with the IEC 61850-9-2 standard. It provides information about, among others, a new group of devices which are currently developed by Mikronika which functionality will be extended with transmitting samples of analog and binary signals using efficient communication connections creating a so-called process bus. Moreover, it discusses the issue of precise time synchronization compliant with the IEC 61588 standard, ensuring correct operation of an entire system. An indispensable element of a modern substation automation system is redundancy on the communication level. This document presents solutions which, in contemporary reality, enable to meet requirements connected with lossless data transmission.