{"title":"Experiments with explosive flux compression Generators Confirming the CAGEN-CALE threshold predictions for internal electric breakdown","authors":"S. Ault, R. Kuklo, J. Chase","doi":"10.1109/MEGAGAUSS.2012.6781430","DOIUrl":null,"url":null,"abstract":"A total of seven shots were fired at the HyperSpectral Sciences, Inc. firing site in Cinebar, WA, in support of the program to elucidate the internal electric breakdown phenomena. Three experiments were full-up HFCG shots. All of the HFCG shots broke down, while the last one exhibited the clearest example of “classical” breakdown. The correlation of the computer model threshold calculation with the last shot is quite good. The use of framing and streak cameras as a diagnostic has proved viable; the contact point as well as the breakdown are very visible. It was found that the electrical arcs that result from the breakdowns do not move. They are overrun by the contact point. The compressed gas in the interior of the HFCG must be taken into account. While it seems quite evident that the breaks are from the stator to the armature, our evidence cannot prove the point. Details of the firing arrangements, the data recovery methods, and the results with comparisons to theory [1], [2], and [3] are presented.","PeriodicalId":299352,"journal":{"name":"2012 14th International Conference on Megagauss Magnetic Field Generation and Related Topics (MEGAGAUSS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 14th International Conference on Megagauss Magnetic Field Generation and Related Topics (MEGAGAUSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEGAGAUSS.2012.6781430","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A total of seven shots were fired at the HyperSpectral Sciences, Inc. firing site in Cinebar, WA, in support of the program to elucidate the internal electric breakdown phenomena. Three experiments were full-up HFCG shots. All of the HFCG shots broke down, while the last one exhibited the clearest example of “classical” breakdown. The correlation of the computer model threshold calculation with the last shot is quite good. The use of framing and streak cameras as a diagnostic has proved viable; the contact point as well as the breakdown are very visible. It was found that the electrical arcs that result from the breakdowns do not move. They are overrun by the contact point. The compressed gas in the interior of the HFCG must be taken into account. While it seems quite evident that the breaks are from the stator to the armature, our evidence cannot prove the point. Details of the firing arrangements, the data recovery methods, and the results with comparisons to theory [1], [2], and [3] are presented.
爆炸流量压缩发生器的实验证实了内部电击穿的CAGEN-CALE阈值预测
在位于西澳Cinebar的高光谱科学公司发射场共发射了7发子弹,以支持阐明内部电击穿现象的计划。三个实验是全量的HFCG射击。所有的HFCG镜头都崩溃了,而最后一个镜头表现出最明显的“经典”崩溃。计算机模型阈值计算与最后一次射击的相关性很好。使用分幅相机和条纹相机作为诊断手段已被证明是可行的;接触点以及击穿是非常明显的。人们发现,由故障产生的电弧不会移动。他们被接触点淹没了。HFCG内部的压缩气体必须考虑在内。虽然它似乎很明显,断裂是从定子到电枢,我们的证据不能证明这一点。详细介绍了发射布置、数据恢复方法以及与理论[1]、[2]、[3]的比较结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信