{"title":"Highly multiplexed DOI PET detector based on SiPM sensors","authors":"R. Chil, G. Konstantinou, M. Desco, J. Vaquero","doi":"10.1109/NSSMIC.2015.7582150","DOIUrl":null,"url":null,"abstract":"We present an efficient readout scheme to acquire the outputs from two tiled SiPM detectors forming an 8×4 matrix of pixels capable of efficiently encoding event position, and that has good energy and time resolution, as well as depth of interaction capabilities. The characterization has been done using a 32×32 matrix of 1.3×1.3×12 mm3 LYSO crystals and a GSO/BGO phoswich illuminated with a 22Na source. Preliminary results regarding spatial resolution show that the detector has a resolvability index of 0.31, an energy resolution below 20% for the 511 KeV peak and a good separation between the two different phoswich crystal layers. Given the simplicity and compactness of the proposed readout, we envision an effective replacement for the conventional high performance PS-PMTs based detectors.","PeriodicalId":106811,"journal":{"name":"2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2015.7582150","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We present an efficient readout scheme to acquire the outputs from two tiled SiPM detectors forming an 8×4 matrix of pixels capable of efficiently encoding event position, and that has good energy and time resolution, as well as depth of interaction capabilities. The characterization has been done using a 32×32 matrix of 1.3×1.3×12 mm3 LYSO crystals and a GSO/BGO phoswich illuminated with a 22Na source. Preliminary results regarding spatial resolution show that the detector has a resolvability index of 0.31, an energy resolution below 20% for the 511 KeV peak and a good separation between the two different phoswich crystal layers. Given the simplicity and compactness of the proposed readout, we envision an effective replacement for the conventional high performance PS-PMTs based detectors.
基于SiPM传感器的高复用DOI PET检测器
我们提出了一种有效的读出方案,以获取两个平平式SiPM检测器的输出,形成一个8×4像素矩阵,能够有效地编码事件位置,并且具有良好的能量和时间分辨率以及交互深度能力。表征是使用1.3×1.3×12 mm3 LYSO晶体的32×32矩阵和22Na光源照射的GSO/BGO光敏开关完成的。空间分辨率的初步结果表明,探测器的分辨率指数为0.31,511 KeV峰的能量分辨率低于20%,两种不同的光子晶体层之间的分离良好。鉴于所提出的读出的简单性和紧凑性,我们设想一种有效的替代传统的高性能ps - pmt探测器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信