{"title":"Highly multiplexed DOI PET detector based on SiPM sensors","authors":"R. Chil, G. Konstantinou, M. Desco, J. Vaquero","doi":"10.1109/NSSMIC.2015.7582150","DOIUrl":null,"url":null,"abstract":"We present an efficient readout scheme to acquire the outputs from two tiled SiPM detectors forming an 8×4 matrix of pixels capable of efficiently encoding event position, and that has good energy and time resolution, as well as depth of interaction capabilities. The characterization has been done using a 32×32 matrix of 1.3×1.3×12 mm3 LYSO crystals and a GSO/BGO phoswich illuminated with a 22Na source. Preliminary results regarding spatial resolution show that the detector has a resolvability index of 0.31, an energy resolution below 20% for the 511 KeV peak and a good separation between the two different phoswich crystal layers. Given the simplicity and compactness of the proposed readout, we envision an effective replacement for the conventional high performance PS-PMTs based detectors.","PeriodicalId":106811,"journal":{"name":"2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2015.7582150","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We present an efficient readout scheme to acquire the outputs from two tiled SiPM detectors forming an 8×4 matrix of pixels capable of efficiently encoding event position, and that has good energy and time resolution, as well as depth of interaction capabilities. The characterization has been done using a 32×32 matrix of 1.3×1.3×12 mm3 LYSO crystals and a GSO/BGO phoswich illuminated with a 22Na source. Preliminary results regarding spatial resolution show that the detector has a resolvability index of 0.31, an energy resolution below 20% for the 511 KeV peak and a good separation between the two different phoswich crystal layers. Given the simplicity and compactness of the proposed readout, we envision an effective replacement for the conventional high performance PS-PMTs based detectors.