Low-energy chirps for bioimpedance measurement

T. Paavle, M. Min, D. Trebbels
{"title":"Low-energy chirps for bioimpedance measurement","authors":"T. Paavle, M. Min, D. Trebbels","doi":"10.1109/TSP.2011.6043702","DOIUrl":null,"url":null,"abstract":"Using of Minimal Length Chirps (MLC) as excitation signals for the bioimpedance measurement is discussed in this paper. It is shown that reducing the length of chirps and thereby minimizing the required signal energy still allows for a fast and wideband estimation of the bioimpedance. This is very important in the field of implantable and wearable devices, where low power consumption is mandatory. In addition we present a practical signal generation solution based on digital low-cost components.","PeriodicalId":341695,"journal":{"name":"2011 34th International Conference on Telecommunications and Signal Processing (TSP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 34th International Conference on Telecommunications and Signal Processing (TSP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TSP.2011.6043702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Using of Minimal Length Chirps (MLC) as excitation signals for the bioimpedance measurement is discussed in this paper. It is shown that reducing the length of chirps and thereby minimizing the required signal energy still allows for a fast and wideband estimation of the bioimpedance. This is very important in the field of implantable and wearable devices, where low power consumption is mandatory. In addition we present a practical signal generation solution based on digital low-cost components.
用于生物阻抗测量的低能量啁啾
讨论了利用最小长度啁啾(MLC)作为生物阻抗测量的激励信号。研究表明,减少啁啾的长度,从而使所需的信号能量最小化,仍然可以快速和宽带地估计生物阻抗。这在植入式和可穿戴设备领域非常重要,因为低功耗是必须的。此外,我们还提出了一种实用的基于数字低成本元件的信号生成方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信