{"title":"Strategies and test structures for improving isolation between circuit blocks","authors":"D. Szmyd, L. Gambus, A. Wilbanks","doi":"10.1109/ICMTS.2002.1193177","DOIUrl":null,"url":null,"abstract":"RF coupling of signals between circuit blocks can be severe. We quantify electrical isolation on concentric test structures using s-parameter measurements up to 50 GHz. The use of deep trenches greatly improves isolation. Guard rings and junction isolation are also beneficial.","PeriodicalId":188074,"journal":{"name":"Proceedings of the 2002 International Conference on Microelectronic Test Structures, 2002. ICMTS 2002.","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2002 International Conference on Microelectronic Test Structures, 2002. ICMTS 2002.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMTS.2002.1193177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
RF coupling of signals between circuit blocks can be severe. We quantify electrical isolation on concentric test structures using s-parameter measurements up to 50 GHz. The use of deep trenches greatly improves isolation. Guard rings and junction isolation are also beneficial.