{"title":"Performance assessment of primary frequency regulation based on static characteristics","authors":"Song Gao, Zening Zhao, Ting Wang, Chao Zhang, Jiandong Wang, Yingkun Han","doi":"10.23919/SICE.2019.8859907","DOIUrl":null,"url":null,"abstract":"Regulation deadband and speed governor droop are two important performance indicators in the primary frequency regulation of thermal power unit. Coal quality, operation mode, and non-linearity of a regulating valve may cause the deviation between the frequency modulation performance index and the set value. In this paper, a static frequency characteristic curve is obtained from the daily operation data of the generator unit, and the method of estimating the deadband and the speed governor droop is proposed. The effectiveness of the proposed method is verified by industrial examples.","PeriodicalId":147772,"journal":{"name":"2019 58th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 58th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/SICE.2019.8859907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Regulation deadband and speed governor droop are two important performance indicators in the primary frequency regulation of thermal power unit. Coal quality, operation mode, and non-linearity of a regulating valve may cause the deviation between the frequency modulation performance index and the set value. In this paper, a static frequency characteristic curve is obtained from the daily operation data of the generator unit, and the method of estimating the deadband and the speed governor droop is proposed. The effectiveness of the proposed method is verified by industrial examples.
基于静态特性的一次调频性能评估
调节死区和调速器下垂是火电机组一次调频中的两个重要性能指标。调节阀的煤质、运行方式、非线性等因素可能导致调频性能指标与设定值存在偏差。本文根据发电机组的日常运行数据,得到了静态频率特性曲线,并提出了估计机组死区和调速器下垂的方法。通过工业实例验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信