{"title":"Tracker calibration using tetrahedral mesh and tricubic spline models of warp","authors":"C. Borst","doi":"10.1109/VR.2004.79","DOIUrl":null,"url":null,"abstract":"This paper presents a three-level tracker calibration system that greatly reduces errors in tracked position and orientation. The first level computes an error-minimizing rigid body transform that eliminates the need for precise alignment of a tracker base frame. The second corrects for field warp by interpolating correction values stored with vertices in a tetrahedrization of warped space. The third performs an alternative field warp calibration by interpolating corrections in the parameter space of a tricubic spline model of field warp. The system is evaluated for field warp calibration near a passive-haptic panel in both low-warp and high-warp environments. The spline method produces the most accurate results, reducing median position error by over 90% and median orientation error by over 80% when compared to the use of only a rigid body transform.","PeriodicalId":375222,"journal":{"name":"IEEE Virtual Reality 2004","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Virtual Reality 2004","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VR.2004.79","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11
Abstract
This paper presents a three-level tracker calibration system that greatly reduces errors in tracked position and orientation. The first level computes an error-minimizing rigid body transform that eliminates the need for precise alignment of a tracker base frame. The second corrects for field warp by interpolating correction values stored with vertices in a tetrahedrization of warped space. The third performs an alternative field warp calibration by interpolating corrections in the parameter space of a tricubic spline model of field warp. The system is evaluated for field warp calibration near a passive-haptic panel in both low-warp and high-warp environments. The spline method produces the most accurate results, reducing median position error by over 90% and median orientation error by over 80% when compared to the use of only a rigid body transform.