{"title":"A high-sensitivity phantom-implantable E-field probe for studies in bioelectromagnetics","authors":"R. Olsen, P. Neelakanta","doi":"10.1109/IMTC.1989.36886","DOIUrl":null,"url":null,"abstract":"The authors address the design, development, and evaluation of a high-sensitivity RF sensor that is useful in measuring specific absorption rate (SAR) that occurs when a full-size human phantom is exposed to radio-frequency (RF) radiation. The probe consists of a small dipole connected to a zero-bias Schottky diode. The detected and filtered DC signal is preamplified and applied to a voltage-controlled oscillator (VCO). The VCO output is transmitted to a receiver by a fiber-optic link. The preamplifier and VCO use very-low-power devices which permit minimum battery drain. The zero-bias detector has a near-zero cut-in (forward) voltage and detects low-level field intensities. The fiber-optic link eliminates RF interference, and the relatively small diameter of the probe permits determination of localized SAR in phantom models. Details concerning prototype development and testing are presented. Initial evaluation of the probe indicated a VCO frequency shift of 1.0 kHz for an internal 29.9-MHz electromagnetic-field intensity of approximately 82 V/m.<<ETX>>","PeriodicalId":298343,"journal":{"name":"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"6th IEEE Conference Record., Instrumentation and Measurement Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1989.36886","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The authors address the design, development, and evaluation of a high-sensitivity RF sensor that is useful in measuring specific absorption rate (SAR) that occurs when a full-size human phantom is exposed to radio-frequency (RF) radiation. The probe consists of a small dipole connected to a zero-bias Schottky diode. The detected and filtered DC signal is preamplified and applied to a voltage-controlled oscillator (VCO). The VCO output is transmitted to a receiver by a fiber-optic link. The preamplifier and VCO use very-low-power devices which permit minimum battery drain. The zero-bias detector has a near-zero cut-in (forward) voltage and detects low-level field intensities. The fiber-optic link eliminates RF interference, and the relatively small diameter of the probe permits determination of localized SAR in phantom models. Details concerning prototype development and testing are presented. Initial evaluation of the probe indicated a VCO frequency shift of 1.0 kHz for an internal 29.9-MHz electromagnetic-field intensity of approximately 82 V/m.<>
用于生物电磁学研究的高灵敏度幻影植入式电场探针
作者解决了高灵敏度射频传感器的设计、开发和评估,该传感器可用于测量全尺寸人体幻影暴露于射频(RF)辐射时发生的特定吸收率(SAR)。探针由一个连接到零偏肖特基二极管的小偶极子组成。检测和滤波后的直流信号被预放大并应用于压控振荡器(VCO)。VCO输出通过光纤链路传输到接收器。前置放大器和VCO使用非常低功耗的器件,允许最小的电池消耗。零偏压检测器具有接近零的切断(正向)电压并检测低电平场强。光纤链路消除了射频干扰,并且相对较小的探头直径允许在模型中确定局部SAR。介绍了样机开发和测试的详细情况。对探头的初步评估表明,在29.9 mhz的内部电磁场强度约为82 V/m时,压控振荡器的频移为1.0 kHz。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信