A method for reducing adaptor misalignment when testing gloves using ISO 10819.

W. Smutz, R. Dong, B. Han, A. Schopper, D. Welcome, M. Kashon
{"title":"A method for reducing adaptor misalignment when testing gloves using ISO 10819.","authors":"W. Smutz, R. Dong, B. Han, A. Schopper, D. Welcome, M. Kashon","doi":"10.1093/ANNHYG/MEF037","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\nInternational standard ISO 10819 was established in order to quantify the vibration attenuation characteristics of anti-vibration gloves. One problem that exists with the standard is possible misalignment of the palm adaptor that is placed underneath the test glove. If the adaptor becomes misaligned, the measured glove transmissibility will be lower than the actual value. A tri-axial accelerometer was installed in the adaptor and was used as the basis for providing visual feedback of the adaptor alignment to the test subjects. The objective of this study was to test the hypothesis that adaptor misalignment could be reduced by providing feedback to the test subjects.\n\n\nMETHODS\nEight male volunteers (mean age 24.8 yr) were used in the study. Each subject performed two sets of tests: the standard ISO 10819 glove test and the modified version. Three different anti-vibration gloves were tested. Glove transmissibility and adaptor misalignment were calculated for each glove. A three-way analysis of variance was used to analyze the results.\n\n\nRESULTS\nA comparison of the two testing methods showed that the modified glove testing method did reduce misalignment significantly, which, in turn, resulted in an increase in the measured glove transmissibility.\n\n\nCONCLUSIONS\nThe proposed method greatly improved the standard deviation of transmissibility and made the test results more consistent.","PeriodicalId":342592,"journal":{"name":"The Annals of occupational hygiene","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Annals of occupational hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ANNHYG/MEF037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

OBJECTIVES International standard ISO 10819 was established in order to quantify the vibration attenuation characteristics of anti-vibration gloves. One problem that exists with the standard is possible misalignment of the palm adaptor that is placed underneath the test glove. If the adaptor becomes misaligned, the measured glove transmissibility will be lower than the actual value. A tri-axial accelerometer was installed in the adaptor and was used as the basis for providing visual feedback of the adaptor alignment to the test subjects. The objective of this study was to test the hypothesis that adaptor misalignment could be reduced by providing feedback to the test subjects. METHODS Eight male volunteers (mean age 24.8 yr) were used in the study. Each subject performed two sets of tests: the standard ISO 10819 glove test and the modified version. Three different anti-vibration gloves were tested. Glove transmissibility and adaptor misalignment were calculated for each glove. A three-way analysis of variance was used to analyze the results. RESULTS A comparison of the two testing methods showed that the modified glove testing method did reduce misalignment significantly, which, in turn, resulted in an increase in the measured glove transmissibility. CONCLUSIONS The proposed method greatly improved the standard deviation of transmissibility and made the test results more consistent.
在使用ISO 10819测试手套时减少适配器错位的方法。
目的建立ISO 10819国际标准,定量测定防振手套的减振特性。该标准存在的一个问题是放置在测试手套下面的手掌适配器可能不对准。如果适配器错位,测量的手套传导率将低于实际值。适配器中安装了一个三轴加速度计,作为向被试提供适配器对准视觉反馈的基础。本研究的目的是验证通过向被试提供反馈可以减少适配体错位的假设。方法选取男性志愿者8名,平均年龄24.8岁。每个受试者进行两组测试:标准ISO 10819手套测试和修改版本。测试了三种不同的防振手套。计算了每只手套的传导率和适配器对中误差。采用三向方差分析对结果进行分析。结果两种检测方法的sa比较表明,改进后的手套检测方法确实显著减少了对中偏差,从而导致测量到的手套传递率增加。结论该方法大大提高了传播率的标准偏差,使检验结果更加一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信