Communication Latency Calculation in Complex IEC 61850 Based Substation

A. Praveen, K. Swarup, Sachin Srivastava
{"title":"Communication Latency Calculation in Complex IEC 61850 Based Substation","authors":"A. Praveen, K. Swarup, Sachin Srivastava","doi":"10.1109/ICPS52420.2021.9670391","DOIUrl":null,"url":null,"abstract":"IEC 61850 has become the de-facto standard to follow for communication in a substation. The use of IEC 61850 based Client-Server communication service and Publish-Subscribe communication-service, which include Generic Object Oriented Substation Events (GOOSE) and Sampled Values (SV) have aided in the deployment of a more communication-intensive architecture in substation when compared to a non-IEC 61850 based substation. Performance of Protection and Control Systems (PACS) is now additionally influenced by the communication system in a substation. The fault-clearance time in an IEC 61850 based substation now includes the operating time of the protection Intelligent Electronic Device (IED) relay and the communication delay between protection IED and a Switchgear Control Unit (SCU). This paper proposes a method to calculate communication latency in a complex IEC 61850 based substation. It is vital to determine communication latency for understanding the overall performance of PACS. Latency calculation is also essential to optimize PACS design to achieve the requirements of various applications. The communication latency calculation method proposed in this paper uses the Substation Configuration Description (SCD) file to accurately determine the communication path and data flow between a publisher and subscriber. The method also calculates the coincident messages or traffic in the communication path between publisher and subscriber, which aids in determining the latency accurately.","PeriodicalId":153735,"journal":{"name":"2021 9th IEEE International Conference on Power Systems (ICPS)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 9th IEEE International Conference on Power Systems (ICPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS52420.2021.9670391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

IEC 61850 has become the de-facto standard to follow for communication in a substation. The use of IEC 61850 based Client-Server communication service and Publish-Subscribe communication-service, which include Generic Object Oriented Substation Events (GOOSE) and Sampled Values (SV) have aided in the deployment of a more communication-intensive architecture in substation when compared to a non-IEC 61850 based substation. Performance of Protection and Control Systems (PACS) is now additionally influenced by the communication system in a substation. The fault-clearance time in an IEC 61850 based substation now includes the operating time of the protection Intelligent Electronic Device (IED) relay and the communication delay between protection IED and a Switchgear Control Unit (SCU). This paper proposes a method to calculate communication latency in a complex IEC 61850 based substation. It is vital to determine communication latency for understanding the overall performance of PACS. Latency calculation is also essential to optimize PACS design to achieve the requirements of various applications. The communication latency calculation method proposed in this paper uses the Substation Configuration Description (SCD) file to accurately determine the communication path and data flow between a publisher and subscriber. The method also calculates the coincident messages or traffic in the communication path between publisher and subscriber, which aids in determining the latency accurately.
基于IEC 61850的复杂变电站通信时延计算
IEC 61850已经成为变电站通信的实际标准。与非基于IEC 61850的变电站相比,使用基于IEC 61850的客户端-服务器通信服务和发布-订阅通信服务,其中包括通用面向对象变电站事件(GOOSE)和采样值(SV),有助于在变电站中部署更加通信密集型的体系结构。变电站的通信系统对保护和控制系统(PACS)的性能也有额外的影响。基于IEC 61850的变电站的故障清除时间现在包括保护智能电子设备(IED)继电器的运行时间以及保护IED与开关设备控制单元(SCU)之间的通信延迟。本文提出了一种计算基于IEC 61850的复杂变电站通信时延的方法。确定通信延迟对于理解PACS的整体性能至关重要。延迟计算对于优化PACS设计以满足各种应用的要求也是必不可少的。本文提出的通信延迟计算方法使用变电站配置描述(SCD)文件来准确确定发布者和订阅者之间的通信路径和数据流。该方法还计算发布者和订阅者之间通信路径中的一致消息或流量,这有助于准确确定延迟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信