Diagnosis of transformer insulation condition using recovery voltage measurements

Mohd Aizam Talib, NoorAzlan Mohd Ghazali, Melvin Christie, Wan Zakaria, Ismail Hashim, Shahan om Uthman, Mohammad Nor Jamali
{"title":"Diagnosis of transformer insulation condition using recovery voltage measurements","authors":"Mohd Aizam Talib, NoorAzlan Mohd Ghazali, Melvin Christie, Wan Zakaria, Ismail Hashim, Shahan om Uthman, Mohammad Nor Jamali","doi":"10.1109/PECON.2003.1437467","DOIUrl":null,"url":null,"abstract":"Moisture is one of the factors that cause transformer insulation degradation. The detection of moisture in oil and paper insulation is crucial in determining the health of transformer insulation system. High moisture content severely degrades the insulating strength of oil and paper and may eventually cause failure. In recent years, new diagnostic and monitoring techniques have been promoted to complement the classical insulation resistance, power dissipation factor and polarization index measurements. The new test method described in this paper is based on analysis of the polarization spectrum traced from the results of recovery voltage measurements (RVM). This method makes possible assessment of the condition of oil/paper insulation system. This paper shows some applications of RVM for determining the moisture level in the power transformers. The possible use of this method as a diagnostic tool for evaluates ageing trends or actual state of insulation is also discussed.","PeriodicalId":136640,"journal":{"name":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2003.1437467","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Moisture is one of the factors that cause transformer insulation degradation. The detection of moisture in oil and paper insulation is crucial in determining the health of transformer insulation system. High moisture content severely degrades the insulating strength of oil and paper and may eventually cause failure. In recent years, new diagnostic and monitoring techniques have been promoted to complement the classical insulation resistance, power dissipation factor and polarization index measurements. The new test method described in this paper is based on analysis of the polarization spectrum traced from the results of recovery voltage measurements (RVM). This method makes possible assessment of the condition of oil/paper insulation system. This paper shows some applications of RVM for determining the moisture level in the power transformers. The possible use of this method as a diagnostic tool for evaluates ageing trends or actual state of insulation is also discussed.
用恢复电压测量诊断变压器绝缘状况
湿气是引起变压器绝缘劣化的因素之一。绝缘油和绝缘纸中水分的检测是确定变压器绝缘系统是否健康的关键。高含水量严重降低油和纸的绝缘强度,并可能最终导致失效。近年来,新的诊断和监测技术被推广,以补充经典的绝缘电阻、功耗因数和极化指数测量。本文描述的新测试方法是基于对恢复电压测量(RVM)结果跟踪的偏振谱的分析。该方法使对油/纸绝缘系统状态的评价成为可能。本文介绍了RVM在电力变压器含水率测定中的一些应用。还讨论了这种方法作为评估老化趋势或绝缘实际状态的诊断工具的可能用途。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信