{"title":"Overreaching of Reactive Reach in Distance Protection Relay for Faults Involving Earth Path and Soil Resistivity as a Limiting Determinant","authors":"Abhishek Kalita","doi":"10.1109/NPSC57038.2022.10069392","DOIUrl":null,"url":null,"abstract":"Overreaching has been a major concern in the transmission line network. Line differential protection to tackle the issue is not available at times due to various constraints (Monetary, OPGW network etc.) Overreaching by a relay at a local bus due to a fault in some other line at remote bus is a major concern as it leads to the blackout in a LILO (Loop-In Loop-Out) substation. Such a scenario occurs during lightning faults and solid ground faults of low resistive nature. Weak infeed from remote end also elevates the condition of overreaching. The following is a case study of such a fault and the steps taken to rectify it. It is a comparative study of the effect of change in “earth/residual compensation factor” on the reactive reach of the relay setting. Changes in the value of earth compensation factor is done by trend analysis of fault in lines over a period of time considering the physical factors associated with the calculation of earth compensation factor.","PeriodicalId":162808,"journal":{"name":"2022 22nd National Power Systems Conference (NPSC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 22nd National Power Systems Conference (NPSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NPSC57038.2022.10069392","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Overreaching has been a major concern in the transmission line network. Line differential protection to tackle the issue is not available at times due to various constraints (Monetary, OPGW network etc.) Overreaching by a relay at a local bus due to a fault in some other line at remote bus is a major concern as it leads to the blackout in a LILO (Loop-In Loop-Out) substation. Such a scenario occurs during lightning faults and solid ground faults of low resistive nature. Weak infeed from remote end also elevates the condition of overreaching. The following is a case study of such a fault and the steps taken to rectify it. It is a comparative study of the effect of change in “earth/residual compensation factor” on the reactive reach of the relay setting. Changes in the value of earth compensation factor is done by trend analysis of fault in lines over a period of time considering the physical factors associated with the calculation of earth compensation factor.