Power Quality Conditioning due to Flickering Loads with Shunt Active Power Filter using Fuzzy-Granular Controller Method

N. Hannoon, D. Ananth, Nabil Hiday, P. Chowdary, V. Chakravarthy
{"title":"Power Quality Conditioning due to Flickering Loads with Shunt Active Power Filter using Fuzzy-Granular Controller Method","authors":"N. Hannoon, D. Ananth, Nabil Hiday, P. Chowdary, V. Chakravarthy","doi":"10.1109/APSIT52773.2021.9641343","DOIUrl":null,"url":null,"abstract":"This paper proposes the modeling and analysis of a three-phase four wire Shunt Active Power Filter (SHAF) based on real and reactive power (PQ) control method for power quality advancement in the electrical distribution system. The electrical distribution system contains loads like diode rectifiers with resistive load and non-linear resistive-inductive (RL) load respectively. The SHAF system construction consists of an isolation T / Hexagon winding transformer and three-phase IGBT H-bridges for voltage source inverters (VSI). It also has a tuned band-pass type passive filter. The main aims of this paper cover design, modeling, construction, and testing of a SHAF prototype for a three-phase four wire nonlinear and unbalanced system. For effective controlling action, an advanced Fuzzy-Granular controller is used in place of a traditional PI controller. This system is capable to mitigate voltage and current harmonics at a low power distribution system. The control method is developed for absorbing higher-order harmonics and store the same in the capacitor and revert it back to the system in the form of the fundamental waveform, thereby filtering action was done. The controllers based on the d-q-0 transformation technique and first-order transfer function model with three individual PWM controllers for three phases were applied to the SHAF. The proposed system is verified with PI, ANFIS, and Fuzzy-Granular controllers using MATLAB/ Simulink and compares the difference in performance.","PeriodicalId":436488,"journal":{"name":"2021 International Conference in Advances in Power, Signal, and Information Technology (APSIT)","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference in Advances in Power, Signal, and Information Technology (APSIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APSIT52773.2021.9641343","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper proposes the modeling and analysis of a three-phase four wire Shunt Active Power Filter (SHAF) based on real and reactive power (PQ) control method for power quality advancement in the electrical distribution system. The electrical distribution system contains loads like diode rectifiers with resistive load and non-linear resistive-inductive (RL) load respectively. The SHAF system construction consists of an isolation T / Hexagon winding transformer and three-phase IGBT H-bridges for voltage source inverters (VSI). It also has a tuned band-pass type passive filter. The main aims of this paper cover design, modeling, construction, and testing of a SHAF prototype for a three-phase four wire nonlinear and unbalanced system. For effective controlling action, an advanced Fuzzy-Granular controller is used in place of a traditional PI controller. This system is capable to mitigate voltage and current harmonics at a low power distribution system. The control method is developed for absorbing higher-order harmonics and store the same in the capacitor and revert it back to the system in the form of the fundamental waveform, thereby filtering action was done. The controllers based on the d-q-0 transformation technique and first-order transfer function model with three individual PWM controllers for three phases were applied to the SHAF. The proposed system is verified with PI, ANFIS, and Fuzzy-Granular controllers using MATLAB/ Simulink and compares the difference in performance.
基于模糊颗粒控制器的并联有源电力滤波器对闪变负荷的电能质量调节
为了提高配电系统的电能质量,提出了一种基于实数和无功控制方法的三相四线并联有源电力滤波器的建模和分析方法。在配电系统中,二极管整流器分别具有阻性负载和非线性阻性电感(RL)负载。SHAF系统结构由隔离T /六边形绕组变压器和用于电压源逆变器(VSI)的三相IGBT h桥组成。它也有一个调谐带通型无源滤波器。本文的主要目的是为三相四线非线性不平衡系统设计、建模、构建和测试SHAF原型。为了有效地控制动作,采用先进的模糊颗粒控制器代替传统的PI控制器。该系统能够在低功率配电系统中减轻电压和电流谐波。该控制方法是吸收高次谐波并将其存储在电容器中,然后以基波的形式返回到系统中,从而完成滤波作用。将基于d-q-0变换技术和一阶传递函数模型的控制器与三个独立的三相PWM控制器应用于SHAF。利用MATLAB/ Simulink对所提出的系统进行了PI、ANFIS和模糊颗粒控制器的验证,并比较了性能的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信