A 21-level (line-to-line) BTB system based on series connection of sixteen converter-cells for power flow control: experimental verifications by a 200-V, 10-kW laboratory system
{"title":"A 21-level (line-to-line) BTB system based on series connection of sixteen converter-cells for power flow control: experimental verifications by a 200-V, 10-kW laboratory system","authors":"M. Hagiwara, H. Fujita, H. Akagi","doi":"10.1109/IAS.2004.1348659","DOIUrl":null,"url":null,"abstract":"A 21-level (line-to-line) self-commutated BTB (back-to-back) system based on series connection of sixteen converter-cells has attractive features as follows: i) Both active and reactive powers can be controlled independently even in transient states, ii) The BTB system produces almost sinusoidal voltage at the AC side without performing PWM (pulse-width-modulation) control, so that no harmonic filter is required, iii) The BTB system provides an active-power response as high as 3 ms. This work presents experimental verifications of the self-commutated BTB system for the purpose of achieving power flow control in transmission systems. Experimental results obtained by a 200-V 10-kW laboratory prototype confirm effectiveness and validity of both the proposed system configuration and control strategy developed in this paper.","PeriodicalId":131410,"journal":{"name":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2004.1348659","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
A 21-level (line-to-line) self-commutated BTB (back-to-back) system based on series connection of sixteen converter-cells has attractive features as follows: i) Both active and reactive powers can be controlled independently even in transient states, ii) The BTB system produces almost sinusoidal voltage at the AC side without performing PWM (pulse-width-modulation) control, so that no harmonic filter is required, iii) The BTB system provides an active-power response as high as 3 ms. This work presents experimental verifications of the self-commutated BTB system for the purpose of achieving power flow control in transmission systems. Experimental results obtained by a 200-V 10-kW laboratory prototype confirm effectiveness and validity of both the proposed system configuration and control strategy developed in this paper.